vokera maxin 24e boilers trips out reg have to press reset button wots up?

Have tried all things suggested by Curtis Patrick and my Corgi engineer is still stumped HELP!

Rands
May 2008
i had the same problem, vokera engineer came out and replaced the ignition module. It totally cured the problem and works totally fine now

andy greenwood
November 2011
its either the reset button itself thats faulty,the overheat stat or the plate heat exchanger needs replacing.bridge the reset & overheat out & try it.if problem still occurs its the ht exch.if prob cured reconnnect stat 1st then reset!

hayden woodhead
May 2008
When it heats up it trips out and its a while to cool down, pump checked and works fine gas valve replaced Dec 07. Ignition has been checked too and the termostato limit 36TXE2 switch has been replaced. But boiler still trips out when its has been on for longer than 45 mins. Even leaving it to cool for 15mins does not help. Could it be spark electrodes?

Rands
May 2008
tell me exactly what happens when you try to fire it up?

pump runs? fan runs? aps clicks? igniters spark?

need to know where in the ignition sequence the problem is to diagnose...

T
May 2008

Automatic Answer

We may have found other answers which could help you.

Click here for Reg Press Button

Mend Heating, Home Heating Systems
Mend repair fix Vokera home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Vokera home heating systems