Recent: Fix food processor motor?

Mend Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Free repair help for home heating systems

Mend > Home Heating Systems

Mend Oil Going 12

Warmflow 50/70 boiler wont fire?

My warmflow 50/70 oil fuelled boiler wont fire keeps going to lockout after 12 secs.
The burner unit is the rdb1 and have done the usual checks.
Have checked i'm getting fuel and have bled the fuel at the pump,fitted a pressure gauge at the pump and i'm getting 100psi when i press the lockout button.
The thermostats are ok and im getting 240v,i have cleaned the photocell and checked the solenoid and all appear ok.
When the lockout button is pressed and the burner is running through its cycle I'm getting a spark and the fuel is coming through the nozzle but the burner just wont ignite.
Could this be a fuel problem is there anything else it can be any help will be very much appreceaited.

Regards Chris

Chris
September 2010

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Oil Going 12

Mend Heating, Home Heating Systems
Free repair help for home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for home heating systems