fan on light ?

I have the fan only light on on my baxi solo 30/80 boiler i have no heating ?? Any ideas whay has happened ?

paul Quantrill
October 2008
If the fan is running then it could be the air pressure switch at fault, When the fan operates the APS senses the movement and the PCB moves on tho the next stage of ignition (pilot & ignition spark)
The tubes to the APS can get blocked or broken which will result in it staying in the fan only mode.
Good luck, hope this helped.