Recent: Recalls for this model?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Valve Boiler Main Combi

Free repair help

We have 28 questions about mending 'valve boiler main combi'

How to mend Valve Boiler Main Combi

Pages 21
Mend sealed system heating
3

converting to sealed system?

Would it be advisable to convert my heating system to a sealed type? The reason I ask is my boiler often makes... [Read more]
Mend pressure boiler constant
1

why am I losing pressure on my Main Combi 24 HE?

Our boiler is barely 18 months old but we've had constant problems with the noise and pressure. it is now at t... [Read more]
Mend combi boiler works heating
4

no hot water?

we lost mains water and the next day we lost hot water, however the combi boiler still works on heating only. ... [Read more]
Mend ravenheat combi csi

Ravenheat combi boiler continually firing then shutting down?

My 3 year old Ravenheat CSI 85A combi boiler developed the following fault: Firstly, the domestic hot water w... [Read more]
Mend system pressure loop

How can I fill system pressure loop?

I have MAIN COMBI 24 HE boiler. When I dont use it, pressure stay in 0 and when I use hot water it goes up to ... [Read more]
Mend heating pressure radiators
3

Baxi Combi 133 HE Plus loosing WAY to much pressure?

Hope you can lend some advise, I recently had the above boiler installed and I am only running 4 radiators at ... [Read more]
Mend combi boiler installed
1

Baxi Combi 133 HE Plus loosing WAY to much pressure?

Hope you can lend some advise, I recently had the above boiler installed and I am only running 4 radiators at ... [Read more]
Mend combi water running
1

Baxi Maxflow Combi Fs?

The heating system works only if there is a call placed on the water ie actually running the water. Once this ... [Read more]
Mend combi boiler steady

How do I fix my Main Combi 24E Boiler leak?

Boiler is 3 yrs old, has been reliable and continues to work but I have a steady drip leak from immediately be... [Read more]
Mend combi tap main
1

Combi boiler?

In the event of changing tap washers whilst you have a combi boiler installed. In turning the main water stop... [Read more]
Mend combi light fault
1

heatline combi pilot light fault?

My heatline combi boiler has developed a fault, I have recently fitted a new bathroom which has involved drain... [Read more]
Mend 102 pressure boiler

Wickes Combi 102 pressure?

My Wickes boiler needs a repalcement pressure valve. My concern is why has the pressure increased. Can it be t... [Read more]
Mend boiler pressure issue
2

Boiler pressure issue (Worcester Greenstar Junior Cond Combi)?

Last night, I noticed 2 of my upstairs CH radiators were cool at the top, so I decided to 'bleed' air from the... [Read more]
Mend main burner fault
1

Sime Super 102 Main burner pulsing fault?

I have a SIME Super 102 combi boiler. When any DHW tap is opened the boiler starts up ok and pilot light comes... [Read more]
Mend constantly boiler heating
1

hailstead combi constantly running?

as soon as you turn the boiler on the heating kicks in,tested both mico s/w on the diverter valve, both ok, d... [Read more]
Mend combi light works
3

How can i fix my combi boiler, Vokera excell, 80 SP?

The boilers pilot light works but the motorised valve allowing the main gas in does not open for heating or ho... [Read more]
Mend 24 combi boiler problem
5

Sabre 24 Combi boiler problem?

With the filling loop removed on my 18 month old SABRE 24 combi the pressure gauge on the heating circuit cont... [Read more]
Mend boiler combi pressure vaillant water system
4

Combi boiler-pressure low-hot water ok?

Hi, I have a Vaillant Turbomax 242/282e boiler and the pressure has dropped to 0.5. Hot water is fine from al... [Read more]
Mend hot heat valve
2

My radiators are only hot downstairs, what is causing this?

My radiators are hot down stairs, however i can not get heat into them up stairs. I have tried bleeding the ra... [Read more]
Mend worcester lights bosch
1

worcester 230 pilot light lights but nothing else?

i have a worcester bosch 230 rsf combi boiler. when a demand is created (ch or hw) pilot light ignites and sta... [Read more]
Pages 21

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question