Mend boiler advice installed

Neighbour's noisy droning boiler?

I would be really grateful for some advice. My new neighbour has had a new Ariston boiler installed and it ma... [Read more]
Mend heating water lights

Please Help me to fix my Myson Appollo Boiler?

when central heating or hot water is put on it lights as per normal,after 2 or 3 minutes it starts banging and... [Read more]
Mend ferroli modena water

How do I drop the pressure from 4 bar on a Ferroli Modena 80 E?

When central heating is on, the pressure bar rises from 1 bar to 4 bar and water starts dripping from the expa... [Read more]
Mend problem ch works fine

Worcester 9.24 Electronic D/H/W Problem?

Hi. We have a Worcester 9.24 Electronic. CH work's fine but when we try to use hot water the boiler never kick... [Read more]
Mend glow worm 50

Glow worm micron 50ff boilerstat?

Hi, I have a Micron 50 ff which seems to work perfectly in that the burner comes on when required and heats wa... [Read more]
Mend boiler central water

How can I fix my Isar HE30 boiler?

I can't get the central heating or hot water to come on. The display is blinking, first alternating with the ... [Read more]
Mend glow ultimate hot water boiler

Glow worm ultimate 60ff?

The hot water works ok when the thermostat is turned up the boiler starts up until the waters is hot But when ... [Read more]
Mend ferroli modena hello

ferroli modena 80 e blowing fuses and no power to fan?

Hello Garry, This is just a friendly email as I have looked at your replies at this url http://www.howtomen... [Read more]
Mend worcester 28i junior

Presure reducing after use on Worcester Bosch 28i junior combi boiler?

The pressure guage on the boiler keeps going down which would suggest a leak. However when the system is check... [Read more]
Mend turn starts fine

how can i fix my glowworm swiftfow 80?

every time i turn the heating on, it starts up fine but only runs for about 10 min`s then goes out but the pil... [Read more]
Mend heating burner going

Vokera 12_24 RSE Mynute Central Heating Boiler Burner keeps going out?

I have a Vokera 12-24 RSE Mynute Heating Boiler(Direct System)When the room thermostat calls for heat the pump... [Read more]
Mend vokera linea 24 boiler

how to repair my vokera linea 24 boiler?

how to repair my vokera linea 24 boiler? my boiler pressure rises to between 2 and 3.5 bars with the heatin... [Read more]
Mend combi se flashing

Brotony Combi SE, flashing 60 light?

According to the 'helpful' manual, it says the 'ionisation circuit board is faulty' So, which ones that. We... [Read more]
Mend baxi 105e flame failure

Baxi 105e flame failure?

I have a problem where the burner ignites and after a few seconds the flames decrease the ignitor sparks again... [Read more]
Mend vokera linea 24

Broken Vokera Linea 24?

Had problems with not being able to get the central heating going and now when it does fire up, the pressure j... [Read more]
Mend water boiler fire combi heating

ICON 23T -No heat or hot water - Boiler starts to fire up !?

ICON 23T Combi. We have no hot water or Heating. The boiler fires up when we switch the hot water tap to f... [Read more]
Mend boiler moved house

How can I lit a Myson 700C Marathon boiler?

I have just moved to a new house. Before I moved in, the main gas valve was switched off by the previous owner... [Read more]
Mend boiler usual fan

how can i fix my myson apollo 30si? boiler?

my boiler when i switch on heating/water clicks, and starts up like usual the fan works, but is not igniting (... [Read more]
Mend puma boiler heating water

Puma 80e Boiler keeps loosing pressure?

I have a Puma 80e bolier and recently the pressure keeps dropping down to nothing therefore I have no heating ... [Read more]
Mend hot heating replacing

how can I fix Combi Ideal Response 120. No hot water/central heating?

I am trying to fix an Ideal Response 120. After replacing the Limit stat, when DHW is turned on initially mach... [Read more]