Mend Ferroli 240 Modena Hello

ferroli modena 80 e blowing fuses and no power to fan?

Hello Garry,

This is just a friendly email as I have looked at your replies at this url http://www.howtomendit.com/answers.php?id=77702 , I hope you dont mind me contacting you but I have had the same problems as this and wanted some advice if possible.

What happened my boiler just stopped working, because what should happen when we put the water on the fan kicks in and then allows us to spark up the electros and get the gas on so we got heating and hot water. That said I have been without any heating or water for a couple of weeks and myself & family are freezing todeath here. I had a so called corgi call but in all honesty he just did not want to no as he said he was on a massive job, but did say its more than likley my PCB board gone as these Ferrolli Optima 701 - 901 are rubbish and they are known for it. Well I did take his word for this and managed to locate a brand new one which cost me £140 instead of £240 the corect retail cost of these. Its easy enough there is just two screws to take out and some spade connectors to pull off, its really easy to do as all details are on the pcb, for eg x5 connectors just come off old one and goes straight on to x5 on the new pcb, and so on. Right I done this but guess what, the fuse is blowing all the time, so what I think I have done now where I did in all honesty put a higher amp fuse in it to re-try, is possibly blow the brand new pcb board. Right this brings me to your details and why I am emailing you, cos what I have done Garry is take the new pcb back off and put the old one back on, and guess what with the new correct amp fuses used every time I put it on it now starts to re-light the led`s but back to begging its blowing them, but when pump lead is pulled off they then come on and stay on for approx 10 secs, and the fuse dont blow.

That said Garry would this mean it is the pump or could it be the fan.??? This is why I have emailed you and would be very greatfull if you could email me straight back with any help regarding same.

Thank You
Phillip

Phillip
November 2007
Hi,I do not know if its the same but the ferroli optima 700/900 series has 3 things which could be blowing the fuse on the pcb.....pump,ignition transformer and fan.Are the connectors on correctly?

chris roberts
November 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Ferroli Modena Hello

Mend Heating, Home Heating Systems
Mend repair fix Ferroli 240 home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Ferroli 240 home heating systems