Recent: Will I need to replace my garden tap?

Mend > Home Heating Systems

Mend Ferroli Modena 80 E Central Heating Pressure Expansion Tank

How do I drop the pressure from 4 bar on a Ferroli Modena 80 E?

When central heating is on, the pressure bar rises from 1 bar to 4 bar and water starts dripping from the expansion tank. I have removed air from everwhere yet the pressure does not drop, and water continues to drip from the expansion tank. How do i reduce the pressure? Help me please!

Ali Dawood
December 2007
Pressure should never reach 4 bar. Pressure relief valve should lift around 3 bar. Can only assume that bar gauge is out of calibration. Pressure rise would indicate expanssion vessel requires replacement.

D.R.
December 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Central Heating Pressure Expansion Tank

Related Questions ...

Mend oil heatslave heating
3

I have an oil Worchester heatslave which is gravity fed central heating ?

and is not pressurised at the moment although I would now like to convert it over and fit a filling loop. It h... [Read more]
Mend central heating pressure expansion tank
1

Why is my central heating system over pressurising?

Why is my central heating system over pressurising? I woke up this morning to hear water running! on investi... [Read more]
Mend combi boiler heat exchanger pressure drop
2

Vokera 28compact combi expansion tank problem?

Since putting central heating on in October I have had a problem with pressure dropping and water coming out o... [Read more]
Mend boiler vaillant water pressure
1

low water pressure F28 lockout, Vaillant Turbomax plus 828E ?

Hi guys, Hope you can help. I've viewed all the relevant and some of the irrelevant posts on similar subjects ... [Read more]
Mend boiler pressure expansion tank
2

Glowworm 330+ Central Heating boiler question?

1. What should the water expansion tank pressure be? 2. The Red guide hand is on 2bar but the pressure (col... [Read more]
Mend central heating boiler pressure
3

with the system drained, what pressure should be in the expansion tank? ?

worcester electronic 9.24. when i switch the central heating on, water pressure starts to raise from one bar u... [Read more]
Mend boiler central heating pressure
1

how do you drop system/boiler pressure on a Baxi 105e combi boiler?

I need to check the pressue in the expansion tank, and re-pressurise it if needed. When the central heating is... [Read more]
Mend boiler central heating potterton
1

Potterton combi 80 boiler?

When central heating is hot, the bar guage goes into the high pressure red section and water comes out of the ... [Read more]