Mend baxi combi 80e
1

Baxi Combi 80e?

I have had no heating or hot water for almost 6 days now. The neon light flashes to say there is a fan/flue f... [Read more]
Mend combi hot demand
9

Baxi combi 105HE boiler fault on the heating side?

I have a Baxi 105HE combi boiler. When the hot water is in demand the boiler will run ok no matter how many t... [Read more]
Mend baxi 105he boiler
2

Baxi 105HE Heating fault?

I have a Baxi 105HE combi boiler. When the hot water is in demand the boiler will run ok no matter how many t... [Read more]
Mend combi hot water ch problem
1

My 105e Baxi combi works fine for hot water - no CH?

Hot water no problem, though when it is finished the flue / fan indicator flashes. I replaced the CH temp sens... [Read more]
Mend baxi problem boiler works fine
5

Baxi Bahama 100 - Hot water problem?

Hi there to anyone who can possibly help me with the above problem. The boiler works fine for central heati... [Read more]
Mend baxi instant boiler
9

domestic hot water problem Baxi 105e instant?

In all respect my boiler appears to do everything it should.No fault warnings,sounds right,fires up on demand ... [Read more]
Mend pump baxi solo
1

pump overrun baxi solo3 PFL?

my baxi solo 3 PFL honeywell printed circuit board ,tells pump to run with no demand on s/v terminal (HEATING-... [Read more]
Mend 80 combi central heating
3

Baxi 80E No hot water, CH ok. !!?

Got a Baxi 80 E Combi, Central Heating is perfect but NO hot water. The Hot Water neon does not illuminate wha... [Read more]
Mend fan run will switch off
2

Baxi 105e instant fan continues to run and will not switch off?

Hi there. I have a Baxi 105e instant boiler. When heating DHW it goes through correct sequence as described... [Read more]
Mend baxi boiler pcb
1

How can I fix my baxi boiler 100HE?

My boiler keeps over heating or going to red lock out, i have just fitted a new control pcb this has not recti... [Read more]
Mend fault pcb required
1

Baxi 105e - traced fault to PCB - spares required desperately?

Does anyone know where I can get spares today? in the Cornwall/Devon area. Got family coming today for new yea... [Read more]
Mend baxi 105e ideas
4

baxi 105e combi pressure @ 3.0 bar?

any ideas? can lower pressure down manually and it also blows off automaticaly at 3.0 bar heating not working ... [Read more]
Mend baxi 100 flow switches
2

baxi bahama 100 combi knackered again-advice requested?

After several flow switches and a new PCB over the years my Baxi boiler has developed another fault. I am assu... [Read more]
Mend boiler fault pcb
1

Baxi 105e fault?

My Baxi 105e comes on with the timer, runs until the house is warm, but later if you go upstairs you can see i... [Read more]
Mend solo pf problem
10

Baxi Solo 50/4 Wall Mounted PF Burner Shutdown Problem?

My Baxi Solo 50/4 Wall Mounted PF gas fired central heating boiler ignites when the thermostat calls for heat,... [Read more]
Mend pcb replaced boiler central heating
3

baxi 105e still problems after new PCB installed?

replaced PCB. boiler will now try to fire up when central heating is selected with constant selected on the ti... [Read more]
Mend boiler baxi combi instant hot water heating
2

why dose`nt my why water heat up(baxi combi instant 105e)?

my preheat on my baxi combi instant 105e works fine ,but when i turn on the hot water tap the boiler won`t fir... [Read more]
Mend water problem works
2

Baxi 105e hot water problem?

I have a pain of a problem with my Baxi 105e. It’s not quite 4 years old, the problem we have is as follows.... [Read more]
Mend baxi combi works
19

Fixing a Baxi 105e Combi which reports a fault when cold, works when reset?

Hi - this has baffled me and the heating engineer I've called in to look at it. My Baxi 105e has been reportin... [Read more]
Mend baxi heating working water
1

Baxi solo 2 heating working but trips out when hoy water is turned on?

The central heating is working, however when the water is switched on the boiler turns off. no heat light etc.... [Read more]
Pages 321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question