Recent: Replace rear right door upper right latch cable - high roof?

Mend Home Heating Systems

Heating, Home Heating Systems howtomendit.com find out how to mend just about anything.
Categories

Mend Worm Burner Lights

Free repair help

We have 20 questions about mending 'worm burner lights' in category Heating, Home Heating Systems which have been answered

How to mend ... Worm Burner Lights

Mend Heating, Home Heating Systems

Glow worm space saver 45-60 cutting out?

My boiler cuts out after 30 seconds cutting off main gas valve so lose main burner and pilot. It had a new t/c... [Read more]
Mend Heating, Home Heating Systems

My Glow Worm Micron 30FF wont light. How can I check whats wrong&fix it?

I have a Glow worm Micron 30FF which was installed new 4 years ago. Since then it has been serviced and a new... [Read more]
Mend Heating, Home Heating Systems

no main burner- Glow worm economy + 80F?

Glow worm economy plus 80F. Fan problem fixed- fan now turns. pilot spark present. pilot light eventually ligh... [Read more]
Mend Heating, Home Heating Systems

Glow Worm 35f Fuel saver won't light main burn?

I have an old glow worm 35f fuel saver, positive pressure boiler. The pilot lights intermittently but won’t ... [Read more]
Mend Heating, Home Heating Systems

My boiler wont start?

I have a glow worm Micron 80FF. The reset button and burner on lights are flashing and the boiler will not fi... [Read more]
Mend Heating, Home Heating Systems

My Glow Worm Micron 40ff boiler isn't working?

My Glow worm Micron 40ff boiler has stopped working. When I turn the hot water or heating on it makes a sligh... [Read more]
Mend Heating, Home Heating Systems

Glow-worm micron 60ff flashing lights?

Fitted this micron 60ff myself 7 years ago . 2 months ago I change pcb and heat sensor on boiler because the f... [Read more]
Mend Heating, Home Heating Systems

Glow Worm 24ci - hot water only luke warm?

Hi All, i have a Glow Worm 24ci about 7 years old. Recently when hot water tap is opened, water only seems ... [Read more]
Mend Heating, Home Heating Systems

glow worm 18 hxi gas valve?

when gas burner lights it makes a noise . as if the burner is not burning all the way round . it then goes qui... [Read more]
Mend Heating, Home Heating Systems

My Fuel Saver Burner goes out?

I have a Glow worm Fuel Saver 55F. The burner lights up for about 60 seconds and then goes out eventhough it i... [Read more]
Mend Heating, Home Heating Systems

Glow Worm Micron 60FF Manual/Help needed?

Hi, our boiler has been intermitently needing resetting, now it has both Reset and Burner On lights flashing g... [Read more]
Mend Heating, Home Heating Systems

Glow worm hideaway 50b is cutting out?

What is causing my G.W.boiler to keep on cuting out? I have cleaned and adjusted the piolit and it lights up ... [Read more]
Mend Heating, Home Heating Systems

Please Help. I have a Glow-worm Micron 40FF?

I have 2 green lights. The reset one is bold green and the burner on light is flashing green. My heating is no... [Read more]
Mend Heating, Home Heating Systems

NO PILOT LIGHT ON GLOW WORM ELITE 21 PLUS BOILER?

THE BOILER IS BY GLOW WORM , THE MODEL IS ELITE 21 PLUS (SERIAL NUMBER (01013677) I CHANGED PILOT INJECTOR AND... [Read more]
Mend Heating, Home Heating Systems

What is wrong with my Glow worm 60FF boiler?

My Micron boiler has developed a fault ie the preset and burner lit lights keep alternating. The book say "so... [Read more]
Mend Heating, Home Heating Systems

Glow-worm space saver 50 B F / boiler goes off once main burner lights ?

Hi, the pilot light will light as i have changed the thermocoupler and the main burner will also light but the... [Read more]
Mend Heating, Home Heating Systems

Whats wrong with my boiler?

I have a Glow worm space saver 38 boiler, which will be replaced next year, when the main burner lights up it ... [Read more]
Mend Heating, Home Heating Systems

glow worm - central heating not working as pilot burner light does not stay?

I follow the lighting instruction, but the pilot burner lights are not holding even after several attempts to ... [Read more]
Mend Heating, Home Heating Systems

Glow Worm Space Saver 38 fault?

It's a really old one but was fine until this morning when I gave it a clean. Hoover in and got all the muck o... [Read more]
Mend Heating, Home Heating Systems

my Glow-worm spacesaver mk2 main burner does not light,?

boiler has stopped heating water, the main burner does not work, pilot light is lit, and the pump runs,new pum... [Read more]

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question