32 mins ago: Will I need to replace my garden tap?

Mend > Home Heating Systems

Mend Glow-worm 50 B F Space Light

Glow-worm space saver 50 B F / boiler goes off once main burner lights ?

Hi, the pilot light will light as i have changed the thermocoupler and the main burner will also light but then you here a click from the gas valve which turns the gas off. Can anyone help please, Ian

Ian
April 2008
Just increased the jet pressure slightly (small screw inset in main control module (mid left )to stop flame sucking away when the main burner comes on and hey prestoits working fine. If when you switch unit on the flame draws away from the thermocouple even for just 1 second the main burner will not come on and the pilot light will go out -- could be my pilot burner nozzle is slightl furred up ... thanks for the heads up saved me £200 quid.... happy chappy !!!

Tezza123
October 2010
is a glow worm ultimate open flue low water content or cast iron

carol oneill
March 2010
check that the sight glass is secure as, if not, the burner pulls air in thro the sight glass hole pulling the flame away from the thermocouple.

Bill
June 2008
Thanks Tony boiler now working fine, top man.

Ian George
May 2008
Thanks Tony boiler now working fine, top man.

Ian George
May 2008
you will see that when you light piliot and main burner comes on the main flame goes all floppy and goes out this is due to main heat exchanger external fines being blocked up not allowing burnt fumes to pass through if the is case heat exchanger requires removing and power jetting clean
or
if pilot jet to small causingforce of main burner to pull flame from thermocouple remady clean pilot jet not with pin but with compressed air can or remove and blow water through

tony
April 2008

Related Questions ...

Mend boiler heating thermocouple
4

glowworm space saver 50 bf?

help my boiler is firing up for about 1 minute then cuts off the pilot light i have changed the thermocouple t... [Read more]
Mend boiler heating gas
1

how do i get my pilot light back on my glow worm space saver 50 mk2?

my pilot light has gone out, ive turned off electric point, turned gas knob to off, ive followed instructions ... [Read more]
Mend heating ignition gas valve
2

Glow worm space saver 38/50 bf boiler wont light?

The igniton will light the piolt light, however, when i release the gas vale button the main burner will not i... [Read more]
Mend boiler gas supply home heating
1

pilot light has no gas even when button pressed?

I have a glow worm space saver 50 boiler and the pilot light went out when I tried to relight it there was no ... [Read more]
Mend heating thermostat gas valve
1

I have a glow worm space saver 38/50 ?

my space saver 38/50 boiler refuses to fire up.pilot light working normally. thermostat in heat position, time... [Read more]
Mend glow worm space boiler
1

My Glow worm Space Saver 50 boiler appears to have overheated?

The boiler was having trouble firing up on Saturday morning, this appears to have been solved by securing the ... [Read more]
Mend space mk 2
1

glowworm space saver 50 mk 2?

i have a problem with the pilot light not staying on,i think its the thermocouple but i cannot get the cover o... [Read more]
Mend boiler heating thermocouple
1

Glow-worm space saver 50 B F will not stay alight ?

My boiler will not stay alight,can get pilot to light but once the main boiler ignites the gas valve "clicks" ... [Read more]
Mend heating boiler glow-worm
1

glow warm space saver 50 boiler balanced flue?

pilot light on fuse ok main burner fails to light has been working for last 4 years so whats gone wrong ?
Mend boiler gas heating
1

Glow Worm Space Saver 50 Mk II - front cover warped?

Hi, BG changed my meter and cut off the gas supply. They couldn't relight the boiler and said it wasn't their... [Read more]