Mend ravenheat boiler fire

Faulty Ravenheat condensing boiler?

My Ravenheat CSI primary condensing boiler will not fire up. I called out a heating engineer who diagnosed a f... [Read more]
Mend boiler pressure board

Worcester 24i combination boiler pressure loss?

Had fan changed, PCB board changed, internal blockage due(manifold changed) water pressure sensor changed. N... [Read more]
Mend wrong boiler several

What is wrong with our boiler? Had several repairs?

Our boiler broke down just 6 months ago where we had it repaired and the switchboard changed. A year before th... [Read more]
Mend changed fan pressure

how do I ignite my boiler?

Thank you for such a detailed answer, that's very helpful. I have one more question, we have changed the fan,... [Read more]
Mend falcon inner boiler

how can i fix combi?

have no ignition on my ferroli falcon 2 combi ,yet when i remove the inner cover the boiler fires.have changed... [Read more]
Mend baxi 105e flashing

need to sort a faulty baxi 105e?

the neons where flashing on the flame and fan faults so changed the flue venturi and the air pressure switch... [Read more]
Mend boiler fire up

combie boiler wont fire up?

i have a jaguar 23 combie boiler,there is no fault codes displayed,the pump runs ,the fan runs but keeps runni... [Read more]
Mend boiler pump runs fan

My Worcester 28i Junior will not spark?

I have a worcester 28i junior combi boiler which will not spark the pump runs, the fan runs which in turn swit... [Read more]
Mend problem currently combi weeks

Worcester 350 - Fuse problem?

I currently have the worcester 350 combi boiler and for last 2 weeks it keeps blowing a fuse. we've had 8 call... [Read more]
Mend ferolli optimax boiler saying f

Ferolli optimax boiler keeps saying F 37?

Ive had numerous engineers now to look at my boiler, the cost is escalating to the point where it would have b... [Read more]
Mend causing running heating

worcester 28cdi fault?

i've got the a 28cdi and it's causing problems. when running on heating it can stay on all the time, but when ... [Read more]
Mend sime format c boiler

having problems with sime format 80 c boiler?

I have changed the diverter valve and water adjuster valve and the led light now flashing to say check smoke p... [Read more]
Mend help combi boiler red

Help with SABRE HE25 COMBI BOILER- RED LIGHT OF DEATH?

Hi, Im after some advise and hoping someone can maybe help me (please!) I have a Sabre HE25 Combi Boiler (sa... [Read more]
Mend potterton profile fan

potterton profile 50e?

The boiler will not start, the fan runs OK but will not following the flow chart supplied by potterton comes u... [Read more]
Mend fault light solve

Fan/Flue fault on 35/80 ie?

I am getting a fault light on fan/flue for the 35/80ie boiler. I have changed the pressure switch but that did... [Read more]
Mend ravenheat boiler pilot

Ravenheat Condensing Fanned Flue Boiler CSI Primary Problem?

The fan comes on the pilot lights the boiler lights then it quickly cuts out and repeats this cycle. The press... [Read more]
Mend prima boiler pressure

Potterton Prima 40f?

Boiler ignites and burners come on with 10mbar burner pressure. However looking through the view glass I get f... [Read more]
Mend potterton ignites burner

Potterton Prima 40f?

Boiler ignites and burners come on with 10mbar burner pressure. However looking through the view glass I get f... [Read more]