Recent: How to recoil the starter spring - Champion R484TR?

Mend Baxi Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend Baxi home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

baxi combi 80 Eco?

A plumber turned the pressure relief valve several times in the anti-clock wise dir ,now the system keeps blowing off to .5 bar no matter how many times i rechange the system to 2.5 bar i have tried turning the valve in the clock wise dir to no avail

kevin
February 2012
for 1 thing,you should not be charging to 2.5 bar, 1 bar is normal. system pressure will increase, as it gets hot, the relief valve operates at 3 bar. as you have it at 2.5 a lot of pressure is going out, when it operates, thats is probably why it drops to 0.5.
Turning the valve should not do anything except release pressure, But it is not the correct way, they can leak afterwards. Why did he turn it anyway, was it leaking? as turning it a few times can flush the valve seat and stop it from leaking.

SD
February 2012
Mend Heating, Home Heating Systems
Click here to mend Baxi home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Baxi home heating systems