water dripping out of overflow pipe from boiler when CH on?

I have a Vaillant combi boiler and when i put on the CH water is dripping from a pipe that looks like an overflow pipe going from back of boiler to outside wall.Does anyone have an idea what the problem might be.Thanks

jane
May 2010
is this a condensing boiler ecotec or ecomax boiler.
if it is this is normal for water to flow from CONDENSATE pipe, as its condensing...otherwise if out of the Pressure relief valve, could be expansion vessel down on air pressure or dirt in seating of prv.

ant
May 2010
Sounds like the safety valve is either indicating a problem or just leaking. Does the pressure gauge go up soon after lighting the boiler? If so the expansion vessel could have failed. I suspect you are regularly topping up the system. If the pipe leaks whilst the system is cold as well then the safety valve is leaking. If only when running them most likely the expansion vessel. (Replacement is £100 - £150 I'm afraid)

Paul Thurmaston, Leicester
May 2010

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Water Overflow Combi

Mend Bathroom Appliances, Baths and Showers
Mend repair fix Vaillant baths and showers

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Bathroom Appliances, Baths and Showers
Mend repair fix Vaillant baths and showers