Recent: Trayford close coupled toilet?

Mend Vokera Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend Vokera home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

vokera mynute 28se. Hoe does it check for water present and pump on?

Is it the same sensor that checks there is water in the boiler before firing and to confirm the pump is running. ?? The boiler at the moment will fire even though there is no water pressure on the boiler gauge. I assune the sensor has been bypassed. Please briefly explain to a newbee.
Thanks Michael

Michael Costello
August 2005
Michael,

I'm not an engineer but, I've had similar problems.
The fault I found with my 28se was the heat exchanger was clogged solid with lime scale. try removing the heat exchanger, flushing through with kettle descaling fluid. it worked for me. Also check that the diaphragm hasnt become stuck, if so strip, clean, grease up (plumbers grease approx £3 for a tiny pot).

Good luck

Pete

pete
September 2005

Automatic Answer

We may have found other answers which could help you.

Click here for Water Pump Sensor Boiler

Mend Heating, Home Heating Systems
Click here to mend Vokera home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Vokera home heating systems