Mend Turn Water Bleed

HOW TO TAKE RADIATOR OFF FOR TILEING BEHIND?

I NEED TO TAKE RADIATOR OFF WALL TO TILE BEHIND . HOW DO I DO THAT . WOULD I NEED TO TURN WATER OFF AND WOULD I NEED TO BLEED IT WHEN REPLACING THANKS

CHARLES MATHER
May 2008
close both rad valves (IMPORTANT:count turns of valve on lock shield side) the get a low tray under one of the valves, and very slowly undo the valve at the radiator, not all the way,
just until you get a small flow of water, when the tray fills, lock it again and empty, repeat process until all water has stopped, then open the radiator air-bleed and expect more water, keep going until empty.

You will need to have some kind of floor protection down, as you will get some black sludge dripping when you move the rad.

When fully empty, undo both valves from either side of rad and lift it clear. (have something at hand to stopper both ends, rag will do) when you have it off you may aswell bring it outside and use your garden hose to flush it out)

Relpace in reverse order, the open valves returning lock shield side back to original position (important!) and bleed of air for bleed valve until rad has filled, make sure to check your boiler system pressure as this will have dropped, use filling loop to repressure to 1-1.5 bar when cold, good idea to maybe bleed all rads after doing this.

Advice, take is slowly, it is easy to do, and ALWAYS spend a bit of time checking for leaks at the rad once it has been replaced and refilled......good luck

T
May 2008

Automatic Answer

We may have found other answers which could help you.

Click here for Turn Water Bleed

Related Questions ...

Mend heating pressure radiators
1

condensing boiler 532/i. ?

i have had to bleed my radiators and now boiler wont work. the pressure is at zero. i have tried to let more w... [Read more]
Mend combi heat exchanger sensors
6

Ideal Combi Logic boiler "L3" fault. ?

Whenever the temperature knob is turned up higher than half way, the boiler shuts down, flashing L and 3. Have... [Read more]
Mend boiler heating pressure
1

Water Pressure Gauge rises too high on my combi?

Dear Friend Well I hope you are a friend because I need some advice, the pressure gauge o... [Read more]
Mend heating pipes water
1

glow worm 24ci?

when i turn my heating on the pipes warm up but the hot water is not getting to my rads. ive bleed the rads wh... [Read more]
Mend losing water air
1

Losing Water?

Our Quattro Gold is losing water out of the overflow. this in turn leads to air in the system. I am having to ... [Read more]
Mend boiler heating radiators
1

What is wrong with the pressure?

Hello I have a Vokera Linea 24, for the past few months the pressure has been going up to nearly 4 each day... [Read more]
Mend boiler central heating radiators
1

How can we fix our hot water?

Last night, we tried to set the timer on our central heating for the first time since moving in, we then had t... [Read more]
Mend Potterton EP2001 Central Heating
3

how can i fix my EP2001 programmer?

drained central heating to add new rad, didn't turn off electric to programmer and now it doesn't work. Had a... [Read more]
Mend combi boiler boiler pressure heating system
1

how can i fix trapped air in my combi boiler?

I have a britony combi 80 boiler and when i either turn the heating on or hot water tap the pressure gauge ris... [Read more]
Mend boiler heating radiator
2

how can i drop the pressure on my 24i boiler?

I topped up the water pressure on my worcesters 24i boiler today and I put too much in.When I turn on the C/H ... [Read more]
Mend boiler heating thermostat
5

Potterton Netaheat 1-16 MkIIF heats up water but not the heating?

It was working fine yesterday and today I put the hot water on and it fired fine, nice hot water no probs. Bu... [Read more]
Mend worcester making turn
1

worcester 241i RSF thumping noise?

My bolier now seems to making a thumping noise when I turn the heating on (not when the hot water's on) thoug... [Read more]
Mend boiler heating radiators
1

glowworm boiler hideaway ff?

I had a burst pipe accidentally put a nail through it, anyway have now mended said pipe it was the hot water p... [Read more]
Mend boiler radiators pressure
2

glowworm 24ci?

hot water ok all day long . when i turn on central heating burner ignites warms up to 30-35 c then shuts down... [Read more]
Mend heating system pressure leak
3

Glow worm 30cxi, leak when I turn blue knob?

Hi I have just removed my radiators to do some decorating. When I had finished I put the radiators back on, c... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...