3 hours ago: Toyota overlocker model 3400 D?

Mend Vaillant

howtomendit.com find out how to mend just about anything.
Categories

Mend Vaillant Vcw Gb 242 Eh

Free repair help

We have 31 questions about mending 'vaillant vcw gb 242 eh'

How to mend ... Vaillant Vcw Gb 242 Eh

Pages 21
Mend Heating, Home Heating Systems

Vaillant VCW GB 242 EH hot water goes cold?

When i turn the hot water tap on in the bathroom or in the bath, or the kitchen the water comes out very cold ... [Read more]
Mend Heating, Home Heating Systems

I can not get C/Heating on VCW GB 242 EH Vaillant Combi Boiler ?

I have just renewed the Divertor valve on my combi I have hot water while switch is in Summer mode, but when I... [Read more]
Mend Heating, Home Heating Systems

My Vaillant VCW combi-boiler doesn't provide hot water for bath?

Although all the controls are turned to maximum my Vaillant VCW GB 242 EH combi-boiler doesn't provide hot wat... [Read more]
Mend Heating, Home Heating Systems

Leaking Vaillant VCW-GB 242 EH Combi-boiler?

I had air in my upstairs radiators so I've bled them and topped up the pressure to just below 1bar. When finis... [Read more]
Mend Heating, Home Heating Systems

leak from a vaillant combi bioler?

i have a leak from the d h w. heat exchanger i belive. it is a black 3 tubed chamber to the left of my bioler ... [Read more]
Mend Heating, Home Heating Systems

VAILLANT COMBI BOILER GB 242 EH LEAKING?

My vaillant wall mounted combi boiler VCW GB 242 EH (GC-No.4704413) is leaking from the right hand side and t... [Read more]
Mend Heating, Home Heating Systems

model VCW GB 242 EH vaillant combi boiler ignition problem?

occasionally, when the boiler ignites,the burners light and then go off, then on, then off again sometimes up ... [Read more]
Mend Heating, Home Heating Systems

vaillant vcw-gb 242 eh not igniting to either heat dhw or ch?

boiler was drained to look at water valve diaphragm as central heating was not working (ie) diverter valve no... [Read more]
Mend Heating, Home Heating Systems

Vaillant VCW GB 242 EH no hot water?

Hi i have a problem that i have not hot water, but my central heating works fine, does it sound like i need a ... [Read more]
Mend Heating, Home Heating Systems

Vaillant VCW GB 242 EH?

I have a vaillant vcw gb 242 eh boiler that was already in my flat when i bought it, i have no idea how old it... [Read more]
Mend Heating, Home Heating Systems

HELP! Vaillant combi inop. No Spark VCW GB 242EH?

I have a Vaillant Combi VCW GB 242 EH and it will not ignite, No Spark, No Gas (No Voltage to Ignition Module... [Read more]
Mend Heating, Home Heating Systems

vaillant vcw gb 242 eh, not igniting?

vaillant vcw gb 242 eh? i have drained my central heating system and switched it off at the boiler, i have ... [Read more]
Mend Household Appliances, Vacuum Cleaners

vaillant vcw gb 242 eh?

i have drained my central heating system and switched it off at the boiler, i have left the boiler on thinking... [Read more]
Mend Heating, Home Heating Systems

Vaillant VCW GB 242 EH, cuts out when upto temp?

My Vaillant VCW 242 EH cuts out when upto temperature. When its fires first time it stays on for 2-3 minutes, ... [Read more]
Mend Heating, Home Heating Systems

Vaillant VCW GB 242 EH?

I have a vaillant vcw gb 242 eh boiler that was already in my flat when i bought it, i have no idea how old it... [Read more]
Mend Heating, Home Heating Systems

What should I replace a Vaillant VCW GB 242 EH with?

I'm thinking about replacing my Vaillant VCW GB 242 EH. To make it as easy as possible I'm trying to find out ... [Read more]
Mend Heating, Home Heating Systems

Where can I get a manual for my Vaillant VCW GB 242 EH combi?

I have a Vaillant VCW GB 242 EH combi which is acting up. Just had a guy replace the pressure release valve fo... [Read more]
Mend Heating, Home Heating Systems

Vaillant Combi Boiler?

I have a leak on the Domestic side of the Boiler It is a Boiler of about 15 years old with an id plate of VCW... [Read more]
Mend Heating, Home Heating Systems

Vaillant VCW GB 242 EH - burner keeps burning with Heating off and DHW Off?

DHW works fine, Boiler on with tap opened, off with tap closed, but reignites after a few seconds on low flame... [Read more]
Mend Heating, Home Heating Systems

vaillant VCW GB 242 EH?

My dad's VCW GB 242 EH was leaking at diaphram unit so we replaced it and also the divertor. However, the igni... [Read more]
Pages 21

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question