Recent: How to Fix Hitachi DZ-MV550A Error Code 2881 | Guide

Mend > Home Heating Systems

Mend Vaillant VCW GB 242 EH Boiler Heating Ignition

Vaillant VCW GB 242 EH - burner keeps burning with Heating off and DHW Off?

DHW works fine, Boiler on with tap opened, off with tap closed, but reignites after a few seconds on low flame with CH switched off. As soon the power is applied to the boiler the CH pump comes on the fan runs and the boiler ignites on low flame with thermostat in the off position. Help!!

Moses
October 2005
water valve sticks in hw position which works by presure diferential,wen a tap is opened a needle is pushed upwards operating a microswitch on the servo valve which then fires the boiler,with age the water valve corodes and sticks and the needle stays in the extended position making the microswitch which keeps the boiler on even tho ther is no demand for heating or hw,you can get a service kit for the water valve but would recmend just changing the water valve and the needle/spindle making sure you clean and lubricate the spindle housing with silcone grease..to check look at the back of the servo valve black sometimes white depends on age with 4 presure differential tubes atached..with no taps on check that the switch behind it isnt made..if it is try push the needle/switch arm back into position manually..email me if you need more info ...ctokeley at hotmail co uk hope that helps dude

toke
September 2009
There was a pin actuator that was also corroded but that the engineer had not encountered before. Allegedly now fixed.

motco
January 2006
Update: The problem still exists but slightly less intractable. Vaillant visiting again in a couple of days - all in the first call-out cost, I hope.

motco
January 2006
Well, £195.00 poorer and I know now that it was the water valve, not the servo valve. Vaillant service engineers are well trained and come when they say they will.

motco
January 2006
This site is only as good as the spirit of the users. When you solve a problem, tell us about how! You should take information of course, but give a bit back or it won't work!

Happy Christmas.

motco
December 2005
Moses, do you have an installation and service manual? If not, let me have an e-mail address and I can scan the relevant pages and send them to you. Check that the return spring on the servo is intact. I am not a service engineer, just an owner and I'm trying to sort it myself. Actually it's my son's flat and I cannot get access often as he's at work.

motco
November 2005
hi motco,
I will try to service / replace the servo valve at the weekend if i get time and then let you know.
Many thanks 4 ur feedback.

Moses
November 2005
Moses. I have been in touch with Vaillant Tech people and they say it's more than likely a sticky servo valve. As I see it only the servo valve or the diverter valve CAN be responsible. There is supposed to be a return spring on the servo valve - check that. I cannot get to mine for a few days, it's in my son's flat and he's out working a lot. If you want to e-mail me my address is callom@yahoo.co.uk

motco
November 2005
No I haven't fixed it yet, I don't know whats wrong. Someone out there, surely knows what could be on the blink,and can help us!!

Moses
November 2005
Moses, I have pretty well exactly the same problem. Have you fixed yours yet?

motco
November 2005

Related Questions ...

Mend boiler ignition fault
1

Home heating systems?

I have a Glowworm 100f gas boiler system It has a fault where the ignition stays on when the pilot light is l... [Read more]
Mend boiler heating thermostat
1

combi oil Worcester greenstar heatslave 12/18 switches off?

I have a internal combi oil Worcester greenstar heatslave 12/18 Its has a built programmer and Hot water t... [Read more]
Mend boiler ignition heating
2

Baxi duo tec boiler showing e133 code and ignition flame not working ?

Since not using my heating during the summer I've just put £35 on my pre payment meter but the e133 is flashi... [Read more]
Mend boiler combi heating
1

my worcester 240 combi rsf boiler makes a clatter noise ?

when firing up with the hot water and sometimes the heating, we have to keep resetting it to get the heating a... [Read more]
Mend heating ignition hot water
1

Flashing reen?

The boiler light is flashing green and then amber for two seconds and back to green.Ive no heating or hot wate... [Read more]
Mend flashing hello stopped
3

Sabre HE 3 second blinking green then flashing red when on?

Hello. My Sabre HE stopped working this morning after working fine. I have done lots of searches and tried t... [Read more]
Mend central heating boiler months ago
1

how can I fix my old glow worm central heating boiler model 65-80?

several months ago the ignition on my conventional flue boiler failed to stay alight and I had an idea that it... [Read more]
Mend boiler combi boiler ignition
1

Vaillant boiler won't stay 'on'?

My Vaillant CH boiler 242 EB Combi - LPG fuel from 2x87kg cylinders Refuses to stay on; when the heating is o... [Read more]
Mend pilot light checked
1

Location of pilot light Thorn Housewarmer Super back boiler?

Just purchased a house with Thorn Housewarmer Super back boiler. Had it checked out and it was working for he... [Read more]
Mend boiler heating pressure loss
1

Loosing pressure ,ignition indicator flashing when boiler goes quiet?

VUW 242 1E loosing pressure when not running,cant find any leaks from outlet pipe,when the boiler goes quiet I... [Read more]
Mend boiler heating hot water
1

My Halstead Ace boiler not working?

My Halstead Ace boiler Appliance number 47 333 16 is not working porperly, the power is there and the timer fu... [Read more]
Mend boiler heating working
1

boiler flooded can it be fixed?

My heating has not been working since October 2011,no hot water either. Told by two plumbers that the ignition... [Read more]
Mend heating solenoid pcb
5

Glow worm ultimate 55f playing up ?

Although the boiler is firing up , after about 10 minutes of heating it seems to stop, start stop start q... [Read more]
Mend combi boiler boiler repair no heating
2

how do I fix my combi boiler, SIME FORMAT 80E?

I guys, never used this site before, though I give it a go. Woke up this morning no hot water and no heating.... [Read more]
Mend Vaillant Combi Boiler Boiler Repair
3

How can I fix my vaillant turbomax vuw 242e combi boiler?

I'm trying for central heating by turning control manually the indicating lights come on for central heating o... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...