Recent: How long does house alarm go for?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Boiler Burner Solenoid

Free repair help

We have 21 questions about mending 'boiler burner solenoid'

How to mend Boiler Burner Solenoid

Pages 21
Mend problem boiler light
1

What is the problem with my Potterton 60e boiler?

Hi I have a Potterton profile 60e on which sometimes the pilot light light's,but the main burner will only ign... [Read more]
Mend burner locks out

minor 1 burner locks out?

5 year old minor 1 oil burner locks out after 5mins of combustion.Engineer purged oil line,adjusted pressure c... [Read more]
Mend worm light pressure
1

Glow Worm 35f Fuel saver won't light main burn?

I have an old glow worm 35f fuel saver, positive pressure boiler. The pilot lights intermittently but won’t ... [Read more]
Mend boiler heating burner
2

Thermeco oil fired boiler nightmare?

For over a year we have had issues with a Thermeco oil fired boiler. Repeatedly we have had the jet replaced ... [Read more]
Mend boiler heating lockout
1

Worcester Oil Boiler Burner Lockout?

Hi. The Worcester Boiler is 6 years old and was last serviced 2 months ago. It goes to "Lockout" when restarti... [Read more]
Mend boiler heating gas
2

my parents boiler is a servowarm condensing boiler. It has no pilot on?

the pilot is not lit so hence no burner action. can i relight pilot with a match , i think there is gas flow. ... [Read more]
Mend oil going 12

Warmflow 50/70 boiler wont fire?

My warmflow 50/70 oil fuelled boiler wont fire keeps going to lockout after 12 secs. The burner unit is the rd... [Read more]
Mend boiler gas valve
1

Boiler gas valve solenoids clicking ?

Potterton Netaheat Profile 80e boiler about 20years old. I have just replaced the gas valve including the two ... [Read more]
Mend boiler burner solenoid
4

Potterton Netaheat mk2 f Burner Not firing?

Fan comes on and burner pilot lights but boiler does not fire up. Checked Solenoid at 2.7k. Any Ideas ?
Mend oil burner problem
3

oil fired burner problem?

hi i have a eurocal boiler with an external sterling burner,i have this serviced anually (cleaned by a qualifi... [Read more]
Mend boiler gas valve fault
2

hOW TO GET MY BOILER TO LIGHT EVERY TIME?

POTTERTON PROFILE 80E. WHEN THERE IS A DEMAND FOR IT TO LIGHT THE IGNITION PILOT LIGHT IGNITES AND THE MAIN... [Read more]
Mend works apart stopped working
2

riello motor no longer works (and yet it did before I took the pump apart?)?

Our boiler stopped working, I ruled out everything except the pump or something on the pump like the valve or ... [Read more]
Mend boiler fine days

likely the pump?

my grant boiler (riello rdb burner) was running fine for a few days after we got some more gasoil fuel, then i... [Read more]
Mend boiler gas valve repair
1

Myson alpha 30/50 B boiler not firing up?

Hi All, The alpha 30/50B boiler was manufactured in 1990 and the pilot light is working.When the unit is swi... [Read more]
Mend boiler fault heating
7

Potterton profile 50e pilot light on but no main burner?

it had been on a twice daily hot water cycle during hte summer, when the wife complained the water wasn't very... [Read more]
Mend riello burner hello
4

RIELLO OIL BURNER - ONLY STARTS WITH KNOCK TO MOTOR !?

Hello everyone My oil boiler (1995) has a Riello G5 burner, it would not start this morning and was on loc... [Read more]
Mend burner ignition pcb
1

why does my main burner keep constantly lighting and going out?

Hi I have a baxi solo wm 40/pf bolier which keeps constantly igniting then going out. The pilot is lit and the... [Read more]
Mend vaillant 242e boiler
2

How can I fix my Vaillant Turbomax 242E heating boiler?

My faithful Vaillant is now 10yrs old with a couple of parts changed over the years, divertor Vv and clock if ... [Read more]
Mend burner pilot light out
2

Burner and pilot light go out together?

thermocouple or gas valve the click is the solenoid on gas valve lifting WILLIAM MCDONALD November 2006 ... [Read more]
Mend boiler burner ignition
1

Potterton Netaheat 10/16 Mk1 main burner cycling on start-up?

Can anyone help with this problem? When the boiler starts, the fan starts (normal), then after a short dela... [Read more]
Pages 21

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question