How to mend ... 105e

Mend boiler baxi dhw

boiler switchs itself of?

baxi 105e replaced dhw & ch temp sensors to rectify fault.....flashing light on fan display. switch of ... [Read more]
Mend baxi combi 105e boiler

how can i fix my baxi combi 105e boiler?

I have just replaced the pcb on my boiler because of a fan fault, However, i now have to turn the hot water s... [Read more]
Mend set boiler morning

How do i set timer on my Baxi boiler 105e?

tried looking on internet - how do I set the timer on my baxi boiler. Now winter is hear, desperately need to... [Read more]
Mend set timer boiler house

How do i set timer on my Baxi boiler 105e?

Want to use timer on boiler to set in the morning and evening. Moved into new house and previous owners did n... [Read more]
Mend combi losing pressure

Baxi Combi 105e Losing Pressure?

My Baxi 105e Combi keeps losing pressure. It'll drop from 2 bar to 1 bar in a few days. All the pipes are sur... [Read more]
Mend boiler heating hot water

baxi boiler 105e wont fire on heating or hot water?

Hi i have tried to start the boiler but it will not fire up on hot water or heating can u advise me ples
Mend baxi boiler pressure

baxi 105e combi boiler?

boiler wont modulate when central heating is on causing pressure to exceed 2.5bar, is it the electric safety s... [Read more]
Mend expansion vessel 105e

expansion vessel on 105e?

when recharging an expansion vessel on a baxi 105e do i have to drin the system
Mend central heating 45

105e?

when my central heating has bean on 10 - 15 min the pressuer go up 4-5 bar
Mend baxi 105e valve pressure

baxi 105e safety valve opening,too much pressure?

central heating on, pressure increase to over 2.5bar causing relief valve to open,Is the safety electrical swi... [Read more]
Mend combi wont turn

have a baxi 105e combi boiler but the heating wont turn on?

the water runs hot and combi seems to be working fine but the central heating wont turn on thermostat turned u... [Read more]
Mend water hot amount

Baxi 105e excessive water run off before it becomes hot?

On a Baxi 105e Comby recently it has become noticeable that when running the hot water the amount run off has ... [Read more]
Mend baxi hot water checked

Baxi 105E no domestic hot water?

have checked the micro switches and DHW pressure differential valve and seem to be working fine yet still no h... [Read more]
Mend change diverter valve

change combi 105e diverter valve?

How easy is it to change the complete valve, I have replaced diaphrams in the past and been in the engineering... [Read more]
Mend baxi 105e boiler

flame failure on baxi 105e?

My boiler is showing a flame failure-any ideas.
Mend baxi 105e low pressure

baxi 105e low pressure?

system needs topping via loop fill daily, outside overflow dripping water please help, thankyou.
Mend too much water pressure

too much water pressure?

we have baxi combi instant 105e,afraid put too much pressure in,reads 3.have bled radiator but in reference to... [Read more]
Mend baxi 105e gas

Baxi 105e?

British gas are telling me i need to fit a magnabooster and a hydroflow for the princely sum of £351. as i... [Read more]
Mend baxi combi 105e

Baxi combi 105e?

Pressure is at 3 constantly. How do you reduce the pressure on this boiler? Should be no more than 2.5.
Mend baxi combi 105e low pressure

baxi combi 105e low pressure?

main pressure is reading below 0.5 the sticker next to it says ' call engineer if below 0.5 ' the water temper... [Read more]