Pages 87654
Mend Heating, Home Heating Systems

Can a bolier fault drop pressure even if there isn't a leak on the system?

My boiler is constantly dropping pressure and coming up with the fault code F.22, yet i can't find a single le... [Read more]
Mend Heating, Home Heating Systems

Fluctuating Pressure in Combi Boiler?

I have an ideal response 80 boiler. The pressure has been high on it (4bar) and last night I reduced this pres... [Read more]
Mend Heating, Home Heating Systems

Baxi 105HE intermittent fault?

Baxi combi 105he boiler. 3 years old. The 50* error LED flashes. (fault in flue or fan?) It goes through the s... [Read more]
Mend Heating, Home Heating Systems

My Potterton Prima F80 is not shutting down?

After many years of service my boiler has just developed a strange fault. Even though the time controller (Hon... [Read more]
Mend Heating, Home Heating Systems

Powermax 135?

I'm moving into my house at the end of next week but the pilot light still needs reigniting on the boiler, as ... [Read more]
Mend Heating, Home Heating Systems

No hot or cold water-Pottrerton Boiler & Accolade Storage Tank Help! ?

Hi all, I have a Potterton Suprima 60L Boiler and an Accolade 144 AA160 unvented hot water storage system. It... [Read more]
Mend Heating, Home Heating Systems

Worcester 19/24CBI Problems (Over Heating, Fail to ingite)?

Hoping that someone can shed a little light on my problem or that this may help someone in a similar position.... [Read more]
Mend Heating, Home Heating Systems

Combi boiler – faulty pressure gauge or water leak?

I don’t know if my combi boiler and system (a) has a water leak or (b) just has a faulty water pressure gaug... [Read more]
Mend Heating, Home Heating Systems

depressure of boiler system?

when i release pressure from boiler system via a radiator does the heating system need to be running
Mend Heating, Home Heating Systems

glow worm 18sxi boiler help?

hi i have a glow worm 18sxi boiler and i (stupidly) bled the radiators while it was running and apparently nee... [Read more]
Mend Heating, Home Heating Systems

Worcester Danesmoor oil boiler venting hot water to expansion tank?

I have a Worcester Danesmoor Utility 26/32 oil fired boiler on a vented CH/HW system. When the boiler is runni... [Read more]
Mend Heating, Home Heating Systems

Loud rattle/wheezy noise from Baxi 35/80 IE boiler?

this started last evening accompanied by fluctuations in System pressure gauge on boiler. On advice from gas ... [Read more]
Mend Heating, Home Heating Systems

solaris 30pc condedencing boiler?

just repaced the pressure switch set the system to 1.5 bar but when the system is running , the pressure goes ... [Read more]
Mend Heating, Home Heating Systems

Vaillant EcotecPlus Boiler --Pressure gauge erratic?

Hi: When my heating is on, the needle of the pressure gauge shoots right up to the red. Then when the heat is ... [Read more]
Mend Heating, Home Heating Systems

ariston eurocombi looses pressure when off?

when boiler is not running pressure falls to below 0.5 bar within 30 mins. when i refill to 0.75 bar boiler ig... [Read more]
Mend Heating, Home Heating Systems

back boiler heating water but not rads?

my back boiler in my kitchin trips out after about five mins when trying to heat rads. It does not trip rcd ju... [Read more]
Mend Heating, Home Heating Systems

worcester 28cd1 EXCESS PRESSURE?

Yesterday we fitted a new radiator to a closed system (non vented), but now the pressure reads up to 3 bar whe... [Read more]
Mend Heating, Home Heating Systems

potterton profile 50e burner goes out?

Having switched on all appears ok.fan, pilot, main burner, all start as usual. Then after a short time main bu... [Read more]
Mend Heating, Home Heating Systems

Riello RDB2 oil burner wont ignite when hot?

I have a Riello RDB2 burner in my boiler. After fuel running out and subsequent re-fill the burner ceased func... [Read more]
Mend Heating, Home Heating Systems

Grundfos Alpha+ 25-60 pump problem?

the Grundfos pump circulates water in my UF heating system however, I have noticed lately that although my liv... [Read more]