Recent: Toyota overlocker model 3400 D?

Mend Riello Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Free repair help for Riello home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Riello RDB2 oil burner wont ignite when hot?

I have a Riello RDB2 burner in my boiler. After fuel running out and subsequent re-fill the burner ceased functioning about 1 week after new delivery. Water/sludge was removed from tank , fuel line, filter and a new nozzle was fitted. Now, the burner fires up fine from cold and will run for 30mins or so untill boiler stat or room stat cuts burner out normally. When the stat cuts in again the burner locks out and will not start. The fan runs and ignition cycle starts ok on pressing red lock-out button, but no fire. If left to get cold the boiler will start ok on pressing lock-out button, and will run happily for long enough to get system up to temperature again - then on next normal stat cut-out the lock-out happens again on stat-on. Any advice on possible cause?

chamomile
November 2009
Replace the coil that has 3 wires, sitting on top of the oil pump. Common Riello problem!

John
November 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Ignite Hot Boiler Running

Mend Heating, Home Heating Systems
Free repair help for Riello home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Riello home heating systems