It looks like the agitator and the drum both are not running together during the spinning cycle. You have to check the bottom of the machine. There is a steel cable attachment for this mechanism near the motor. One end of the cable is attach to a plastic catch and other side is attach to a electrical attachment. Check the plastic catch for the cable disconnection. Re fix the cable on to the catch. If plastic is worn out, use something (cable tie or tape) to keep the cable in place.
wicky.
December 2007