Mend Neff Removed Unit Checked

Neff H5474N0GB tripped 32A MCB now dead ?

Removed from unit, checked plug fuse ok. Removed cover, checked cable up to main PCB. No S/C but cannot work out how to remove PCB next to magnetron fan under cavity to fault find. All door switches ok. Any clues?

Stroller55
December 2012
you better be VERY careful you dont kill yourself,the capacitor stores a lot of power,even when the oven is turned off,we use a prob to dischage it to earth,the fault will not be in any of the pcb,s it will either be the transformer,capacitor,or magnatron,you need a megger to test these units,

mm
December 2012

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Removed Unit Checked

Mend Kitchen Appliances, Microwaves