Mend Stop System Turned

bar pressure wont stop rising when the system is turned on?

how can i fix it ?

Declan
January 2012
the expansion tank in your boiler needs to be replaced it all depends the make and model of your boiler how difficult it is as some have to be taken off the wall

annon
January 2012
It will only go to 3, An overpressure release valve will then open, if it is going up that much, water getting into system, check fill loop valve, make sure it is turned off fully. Normal pressure cold system, usualy 1 bar, above that it could go to 3 on heating, depending on system size, If it has just started doing it, drain boiler down, make sure that expansion vessel is empty, refill system, If water filsl expansion vessle, no buffer for water expansion, so pressure will go up high