Recent: Safely remove screen protector from a Macbook Air?

Mend > Caravans/Motorhomes

Mend PP C2 R Fuse Working Water

my cassette pp c2 r will not flush?

Hi I have a cassette PP C2 R toilet and it will not flush. I have checked the fuse and that all seems in working order. I have also ran water through the water fill funnel to check for anything blocking it. Still no luck, any ideas?

Ruth
August 2011
FOLLOW THIS LOT I COMPILED THERE'S A LOT COPY AND PASTE INTO WORD FILE

PAGE 1 OF 3 for Thetfords C2 bench toilet, not moder swivel ones.
see page 3 on Thetford access at end of this info.
GOOD LUCK! from Lunar owner.

Note: Compiled because Thetford do not cover possible jammed pumps or other faults like block terminals going ‘manky’ and arresting current.
As for micro switches supplied by another camper who gave permission to add what he sent me after he contacted me about his pump.

REPLACING / FREEING AN ELECTRIC PUMP IN C2 BENCH STYLE THETFORD CASSETTE TOILETS.
If you are not clear on what to do then e-mail me again.

FREEING A JAMMED PUMP
If you know there is current to the pump go to ‘To access the pump’
An easy test to find out if current is reaching the pump carry out the following..
power up your 12 volt system.
Turn on the 12volt toilet cubicle light or if there isn’t one, one in the saloon area you can see [one over the sink/hob if there is one will do if like mine opposite toilet].
Press the toilet flush and take note if the light dims then goes back to normal on releasing the flush button. If it does it proves power is reaching the pump but the pump impeller is either jammed or the pump is knackered. Or use a multi meter.
If no current at all check the fuse in the holding tank housing, to the left I think.

Once in to tank check the flush tube is connected to both the pump and the side of the toilet. If yes carry on to remove pump then pull flush tube off pump, or just pull it off if you need more room to remove pump..

To access the pump remove the toilet roll holder. PULL up on the holder housing this, it’s a push fit giving access to the water tank. It may need easing around the edges. Vaseline edges before replacing when repair completed to make further removal easy.

You will see the pump flush tube follow down in to tank and there is the pump in a cage held by one screw undo screw lift cage and pump from tank.

To free the impeller on jammed pump remove the pump as above turn it upside down and with small screwdriver turn the impeller about three turns until it feels to be running free . Don’t fix pump back in position just drop it in water, either in the tank or a bucket of water as long as It’s submerged [submersibles need to be wet, running dry damages them]. Oh! make sure the flush tube is still connected or you’ll get wet. If it works job done.

To replace a pump. WARNING! [ DON’T TRY PULLING EXISTING PUMP WIRE OUT FROM SWITCH CONNECTIONS YOU WILL NEVER GET THE NEW WIRE IN WITHOUT TAKING TOILET APART. SPLICE IN NEW PUMP WIRE.
Cut away the existing pump about six inches or 150mm up the cable from the pump and note one wire has a tracer [secondary colour] in the wire the secondary wire on new pump must be connected together don’t connect a plain single colour to a wire Pwith a tracer colour. Fit on each of the wires one of the heat shrink joints then twist
Page 1 continued. so it doesn’t go into four pages)
the wires together. One with tracer [Secondary colour] to the new pump wire with secondary colour. Then connect the two single colour wires together. Slide the shring joints over the joints and heat shrink them down. Then wrap tape around ends of shrink joints to ensure seal. Stow the joint section on the shelf at back of tank so it’s out of the water.
PAGE 2 OF 3

SHRINK JOINTS. [search internet for supplier if local shops don’t stock.]

You can purchase from car spares small shrink wrap sleeves heat sealed for the wire joints just remember to fit them on the cable before connecting wires together. Simply slide sleeves over joined wires and follow heat application instructions.
You could add some water proof tape after to be sure.

Re fit flush tube to new pump and test using a bucket of water to submerse the pump. Remember don’t test any pump dry it will damage them.


From another forum reader haven’t got his mail address.

volt drop can be a bitch to trace. could be a dirty / bad connection or switch. what ya need to do is test the cables with a low reading ohm meter. should get very low reading ie 0.5 ohms. (obviously with the switch in closed position) another way to test is to get some cable, run it from battery direct to pump (a similar length to what's installed) if the problem is still there the battery needs fully charging (even new ones can be down on power without a good solid charge up) if the pump works ok with temp wiring ya need to check voltage going into the first switch and then coming out, same with 2nd switch if 12v in and 12v out. this will tell if the switch contacts are dirty. *To see if the battery is fully charged or not, switch on a couple of lights and test voltage at battery terminals, should still give at 11v. with nothing switched on at all you should get at 13.2 volts. (6 cells at 2,2v /cell)
if everything checks out, ie battery good, 12v out of switches, then the negative from the pump to battery is suspect. again, can be checked with temp wire from battery to pump.



ADDENDUM: Pump repair/replace look also for a bad joint in cable if current drops or not showing and fuse is ok.





Addition with permission from another camper

REPLACING TOILET MICRO SWITCHES.
• I assume he means the flush turn knob can be removed this way once screws out of cover/s



Hi Bob, many thanks for your very quick return e'mail, which is a great help, with the toilet out, I have been able to test all switches, but I am going to replace them, as its very easy whilst toilet holding tank is out, I can tell you, that the only way to replace switches is not through the turn handle, if you open toilet door and swing out flush filler unit, then remove blanking plate,
• ( just held in by push pop ), you will see a long grey cover held in by 4 screw and one up inside the other twist unit with micro switch attached , pull out this unit, and the long grey cover will drop down with the other micro switch inside it, pull apart cable connecters and *the cover unit can be removed from inside the toilet and very easly replace switches, put back in reverse order, hope this helps,

NOTE: In case none helps then below is access to Thetford website and on page 3 as indicated is a ‘Ask Thetford’ click on that and fill in details.


Thetford pdf accesss :

UK www.thetford-europe.com

Australia www.thetford.com.au (Even get request from Australian campers)

Australia site has stockist list.

HOME PAGE SELECT ENGLISH {if in Australia forget this selection)
NEXT PAGE SELECT CUSTOMER SERVICE (top line)
NEXT PAGE SELECT USER INFORMATION (left of pic) also 'Ask thetford' is on this page.
NEXT PAGE SELECT REPAIR INSTRUCTIONS (left of pic)
NEXT PAGE SELECT BUILT IN TOILETS [top right of pic]
NEXT PAGE SELECT This is where you select your toilet range. Search alll if unsure of type/range
NEXT PAGE PDF Files You should be in the pdf folder list on your Thetford toilet. Start downloading.


To direct link to the Thetford download site type in the following
www.thetford.eu/web/show/id=51498/langid=42


Don't bother for Thetford fridges they tell you for safety reason to take it to a service centre

BOB
August 2011

Automatic Answer

We may have found other answers which could help you.

Click here for Fuse Working Water

Related Questions ...

Mend How to mend it?
1

Tefal gv9060go/23c?

Hi We have a Tefal Steam generator GV9060/23C which was working perfectly. When my wife plugged it in, the pl... [Read more]
Mend washing machine filter drain
1

How can I fix my Beko WM5102W Washing Machine - White?

I recently had to empty the filter from my washing machine because it would not drain and it worked fine after... [Read more]
Mend dishwasher no power kenwood
1

No Power to Kenwood dishwasher?

Hi.Last night switched on dishwasher(Kenwood KDW60W10) as usual,but came at the morning and no working.Looks l... [Read more]
Mend water pump stopped
1

207 Window Water Pump?

My washer has stopped spraying and there is no noise from the pump. After some reading I am guessing the fuse... [Read more]
Mend heating boiler hot water
1

boiler stopped working?

My ariston clas he has just stopped working there seems to be power to boiler checked fuse and you can hear ... [Read more]
Mend caravan toilet pump
1

Caravan toilet Water keeps on flowing Thetford C-200 CWE?

As soon as I turn on the poer in the caravan the toilet pump starts working and flushing the toilet. I had to ... [Read more]
Mend heating boiler valve
3

Glow-worm 30cxl?

Started off blowing 3amp fuse in boiler, water cold but heating working ok, engineer came out and fitted a ser... [Read more]
Mend washing machine electricity fault
1

Electricity turns off immediately when our LG Washing machine is on?

My LG washing machine is 3 year old, was working very well. It was on the load and suddenly the electricity we... [Read more]
Mend boiler overheating hot
3

is my boiler overheating?

I have no experience with boiler, I touched the flue duct on the top of the boiler, it's hurt, very very hot... [Read more]
Mend working great lost
2

blowing fuses?

I have a Hotpoint Aquarius DF61 and has been working great until it lost all power when the dial got round to ... [Read more]
Mend washing machine working
2

Our washing machine hotpoint wmd960g isn't working?

Hi there. Our washing machine hotpoint wmd960g isn't working. At first there was a burning smell inside the m... [Read more]
Mend washer pressure fuse
1

How do I fix my Performance PRO1600PWA washer?

I use my pressure washer and suddenly it stop working. Check the fuse and is ok. There is water coming but no ... [Read more]
Mend heating plumbing repair
1

how can i fix my hot-water cylinder?

for some reason my cylinders stopped working,the fuse on the meter-board was blown so i fixed it and its still... [Read more]
Mend boiler central heating programmer
2

Potterton Programmer not controlling stat?

I developed a fault on my Potterton system as a direct result of trying to change the in room stat (Potterton ... [Read more]
Mend cooling radiator renault
1

where is relay for the fan found in renault modus 2005?

My radiator fan is not working even when water boils,checked fuse fine,also fan relay where is is situated?

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.