Recent: Will I need to replace my garden tap?

Mend > Convector Heaters

Mend Creda 79141 Heating Temperature Control

Creda automatic storage heater 79141?

I have two dials - how is the best way to use them

1. Room Temperature

2. Adjust set control.

Thx a lot

susie
October 2010
number of elements depends on heater but i think in your case there is 3.If you remove front cover and look inside at the bottom of heater you will see the pot connectors that the elements are connected into if there are 3 the total resistance of the heater should be about 22ohms if one has gone it will be around 33ohms,and yes they are easy to change

steve.e
October 2010
Thank you steve.e... another question on this matter.

My electrician said although the 79141 is an older model he thought they were quite good the bricks being larger?? One of the heaters might need a new element, is this easy to fix. How many elements in each heater.

sorry that's 3 questions. This is a sheltered housing flat in the middle of two floors and the building seems warm anyhow - also having storage heaters on the communal landings

thank you

susie

susie
October 2010
the set control is how much charge the bricks take offset by the room temperature,this why it is automatic.the room temp opens a flap inside which lets out heat from the bricks.If you are out all day set room temp to min to keep heat in untill you need it.otherwise set both half way if room is too warm turn output down it is largely a question of trial and error to set best comfort control

steve.e
October 2010

Related Questions ...

Mend heating control problem
1

Heating control problem?

Heating control only going up slightly so we cannot tell if the oven is reaching the temperature requested.
Mend thermostat central heating temperature
1

Help to fix a room thermostat, please?

I have a Drayton Digistat RF1 Wireless System to control my central heating and whatever temperature I set it ... [Read more]
Mend heater repair no heat
1

How Can I fix Dimplex Exbury 2KW heater? ?

The lighting works but no heating. I manually adjust the thermostatic round heating control knob concealed beh... [Read more]
Mend boiler heating thermostat
1

combi oil Worcester greenstar heatslave 12/18 switches off?

I have a internal combi oil Worcester greenstar heatslave 12/18 Its has a built programmer and Hot water t... [Read more]
Mend Danfoss Thermostat Heating
1

danfloss fp715si programmer?

My above programmer is malfunctioning the programme has stopped working although the heating is on continuous ... [Read more]
Mend oven thermostat electrics
1

Zanussi Oven Tripping Electrics?

Hi We have a built in Zanussi oven. Usually when the oven or grill reaches the desired temperature set on ... [Read more]
Mend heating temperature control
1

How can I fix a heating problem with our YKEMC307KS0 oven?

We have a temperature control problem with our Kitchen Aid YKEMC307KS0 oven/microwave combo unit. When you se... [Read more]
Mend central heating system
1

Spectrum Fuel-Miser Mk IV?

My central heating system has a Spectrum Fuel Miser Mk IV which provides: . Electronic temperature control of... [Read more]
Mend boiler thermostat heating
1

temperature control gauge boss therm bps242rf?

Cannot control heating does not matter which I use degree from 20.5 to 22.00 still takes the same time from sw... [Read more]
Mend heating temperature control
1

How to set Landis & Steafa RW89 onto auto?

I have a Landis & Steafa RW89 control and it has been wired incorrectly so the heating can only work if the wa... [Read more]
Mend central heating hot water boiler
1

heating system?

I had a glow worm 24hxi boiler fitted to my existing y plan system using the original controls(programmer,room... [Read more]
Mend Saunier Condens Heating
1

How to increase Heating temperature on Saunier F30E?

The control on my Saunier Thema Condens F30E wont let me set the Heating water temperature higher than 50 degr... [Read more]
Mend heating boiler temperature
1

I have no control over the hot water temperture from my high flow 400 boile?

Worcester Bosch changed the heat exchanger in my high flow 400 boiler and did some upgrades since then I have ... [Read more]
Mend thermostat boiler heating system
1

Drayton Wireless System RF1 / Worcester Boiler?

I have a Drayton Wireless System RF1. The thermostat is apparently working well: it indicates the temperature ... [Read more]
Mend How to mend it?
1

How can I upgrade my Worcester 350 heater control?

We have a Worcester 350 combi-boiler with a UT2 single-channel time switch to control the central heating. Tem... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Convector Heaters ...