Mend Worcester 24i Boiler Water

Trying to repair Worcester 24i RSF combi boiler?

After initailly calling for hot water, the boiler will keep re igniting after 5 mins of hot water. We have removed the fan to clean any dust debris, and if we blow in the red pipes it will continue with a good hot supply. Fan seems ok. Do you think this could be the air pressure switch?

Baker
March 2010
Hi, this is Worcester, Bosch Group

We offer technical advice for installers on our website: www.worcester-bosch.co.uk.

Our technical team can also help with enquiries - please call 0844 892 3366.

We look forward to helping you.

Worcester, Bosch Group
March 2010
clean out the venturi in the fan, this is a common fault which can cause the boiler to cycle