Mend Vokera Linea Plus Boiler Combi

Vokera Linea Plus keeps cutting out and displays code 01?

My Vokera Linea Plus combi boiler keeps cutting out and displaying code 01. temperature LED drops rapidly and then displays code 01. has also displayed the letters CO. Any ideas? Local firm said it might be the control panel but advised against fitting one until it packs in completely. It is driving us nuts! Any ideas?

Andrew Sykes
March 2006
how to fix 01 code coming on every hour,new exhusd fitted one week ago still not working

Grace Smith
February 2014
If boiler showing 'CO' try pushing once on a switch located on main PCB near timer and room thermostat connections. If that doesn't resolve it then push the switch once again to reset it two previous state. There is a similar switch on display PCB, try pushing it once. This may get rid rid of the 'CO' problem. These switches are used when analysing Carbon Monoxide (CO) levels in exhaust gases.

Guest1,000,000
April 2013
Just had the same fault. Luckily had boiler insurance. They've just replaced the main PCB and the small one behind it as they damaged it, a new gas valve and reset it all. Seems fine now though the parts and labour are probably more than the boiler is worth especially if you add in the new main heat exchanger they fitted last year. Fingers crossed all will stay ok. Incidently all the engineers who have worked on this boiler hate it and unless they have no choice from their employer they dodge any repairs and pass the job to someone else.

Cratchet
December 2012
exactly same problem - swapped with main pcb board
from sisters boiler (linea max) and worked ok. So i would say the problem is main contol board.

Sav 2204
February 2010
I have seen the CO problem on two other Linea Plus's which I installed about 10 years ago. One also suffers from intermittent 01 faults. Gas pressure setting on these is a total pain. These boilers were over-complicated in design and really represented the last gasp of the traditional low water content boilers before condensing boilers with zero-rated governors became the norm.

Shane
January 2010
co means the boiler is in its service mode,which means running at max, usually if u get intermit 01 code it is the ignition pcb thats faulty either on the gas valve or pigy backed on the main pcb depending which linea u hav-cannot understand why it shows co though????

steve
April 2006

Related Questions ...

Mend combi boiler burner vokera
6

Vokera Maxin 28e combi boiler, DHW runs hot and cold?

A few months ago DHW temperature started to fluctuate mildly between hot and warm. This problem got worse so a... [Read more]
Mend boiler heating pressure
1

how can I fix my Vokera linea 24 Combi?

the boiler cuts out whenever I use either the hot water or the central heating. lo displays after I re-press... [Read more]
Mend combi boiler vokera heating
1

how can i fix my combi boiler.vokera 29 he?

amber light lit. how do I reset it.
Mend boiler combi vokera
1

vokera he combi boiler hw works ch all dead can anyone help?

when I turn remote to call heating there is nothing at all its dead no sound at all hot water is working fine
Mend boiler heating leak
2

Pressure too high on vokera combi boiler and automatically turns off?

Tried bleeding the vokera combi boiler to decrease pressure as it was way beyond the 3 mark but nothing happen... [Read more]
Mend boiler combi central heating
1

how do you adjust the pressure on a vokera combi boiler?

Pressure right down to red . Central heating working ok but no hot water.
Mend vokera boiler combi
1

Vokera Boiler combi?

The boiler is showing a red light constantly! its locked out. What could the problem be
Mend boiler central heating hot water
1

How can I fix a Vokera linea combi boiler?

I have a Vokera linea boiler, the central heating seems to be fine, but we have no hot water. Does anyone know... [Read more]
Mend boiler leak combi
1

How do I fix my boiler water leak?

Vokera linea 28 combi boiler, water leak from underneath, replaced the pressure relief valve as I thought and ... [Read more]
Mend combi boiler morning light
1

How to restart a Vokera Syntesi 35 combi boiler?

My boiler has cut out, it was ok this morning then just cut out. I cannot re light it?
Mend boiler heating pressure
1

Fault with boiler. ?

I have a Vokera HE combi, bout 4 / 5 yrs old. I need to keep topping up the water, when the pressure drops...... [Read more]
Mend boiler overheat expansion vessel
1

Vokera Combi overheat?

I have avokera combi and it over heats, so far we have replaced the Expansion Vessel and the PRV, signeficant ... [Read more]
Mend thermistor vokera combi boiler
1

replacing thermistor?

How to replace thermistor from vokera option combi boiler.
Mend boiler heating hot water
2

hot water?

I have vokera option combi boiler hot water adjustment is on full position, low warm water is comming, but not... [Read more]
Mend combi boiler hot water vokera
1

vokera Linea24 combi boiler?

I am unable to get hot water. I have checked the boiler the heating is working my gas fire is working but the ... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...