my Vokera compact boiler starts up fine when hot water is called for but before the water gets warm/hot the burner stops for a few seconds and then starts again. This pattern is repeated constantanly. I have checked the tube to the air pressure switch and that is clear and fine, any suggestions.........
sounds possibly like minimum gas setting is not set
10.1mbar high 1.9mbar low
steve
October 2008
Check the electrical output of the air pressure switch carefully with a multimeter (careful -ac mains present). If it is tripping out the venturi needs cleaning (not the silicone tubes, the venturi section). >>This is a job for a Corgi man