Mend Heating, Home Heating Systems

baxi 105e diaphragm kit?

Hi all, i believe there are 2 different diaphragm kits for this boiler, i.e 5111137 and 5111140. is there ... [Read more]
Mend Heating, Home Heating Systems

Intermittent hot water on Baxi 105e?

Hi,my boiler has developed a fault on DHW supply,when asked for hot water, system fires up runs for 30 seconds... [Read more]
Mend Heating, Home Heating Systems

how to fix baxi 105e c/h fault?

hi guys /girls, i have just fitted a new diaphragm in differential valve then put it all back togeth... [Read more]
Mend Heating, Home Heating Systems

Baxi combi 105e Hot water keeps locking out ?

I have just changed the diverter valve on my Baxi 105e due to the normal fault of heating up the radiators whe... [Read more]
Mend Heating, Home Heating Systems

How do i replace the o ring on the H/W valve?

Hi, Baxi 105e boiler is whistling when heating is on, if i run hot water tap it stops, have read that it can b... [Read more]
Mend D.I.Y, Plumbing

no hot water and pressure valve is on red and water is leakiing outside?

I have installed a baxi combi 105e; serial MBKo451 compno 2478726/00. My combi boiler is playing up. For mo... [Read more]
Mend Heating, Home Heating Systems

baxi 105e combi boiler?

boiler wont modulate when central heating is on causing pressure to exceed 2.5bar, is it the electric safety s... [Read more]
Mend Heating, Home Heating Systems

baxi 105e safety valve opening,too much pressure?

central heating on, pressure increase to over 2.5bar causing relief valve to open,Is the safety electrical swi... [Read more]
Mend Heating, Home Heating Systems

Baxi 105E no domestic hot water?

have checked the micro switches and DHW pressure differential valve and seem to be working fine yet still no h... [Read more]
Mend Heating, Home Heating Systems

how can i fix my baxi combi instant 105e?

my baxi combi instant 105e keeps loosing water pressure every 1-3 days, i keep topping it up and it will go ba... [Read more]
Mend Heating, Home Heating Systems

boiler?

i have a baxi 105e combo boiler and it is dripping water frome the dhw pressure differential valve at the fron... [Read more]
Mend Heating, Home Heating Systems

baxi combi 105e filling valve stuck?

filling valve is stuck and pressure is on 0 how can i raise pressure?
Mend Heating, Home Heating Systems

Baxi Combi Instant 105e hot water works but no heating?!?

Hi I have a Baxi Combi Instant 105e. The hot water preheat function works, and so does the normal hot wa... [Read more]
Mend Heating, Home Heating Systems

hot water luke warm when heating off?

Baxi combi 105e hot water luke warm when central heating off, also noticd when central heating off heated towe... [Read more]
Mend Heating, Home Heating Systems

baxi 105e?

i have no hot water on the ground floor & water is dripping from pressure relief valve pipe,as system pressure... [Read more]
Mend Heating, Home Heating Systems

domestic hot water problems baxi 105e?

when i turn on hot tap boiler fires as normal the water heats up normally but there is a squeeling noise from ... [Read more]
Mend Heating, Home Heating Systems

Baxi 105e clunking noise every time I turn a hot water tap off?

Baxi 105e 4 years old. Whilst the boiler seems to operate properly, every time you turn off a hot tap in the h... [Read more]
Mend Heating, Home Heating Systems

how can i fix my hot water, baxi 105e combi boiler?

i recently fitted a new set of mixer taps with shower head attachment to my bath, but when i turn the hot tap ... [Read more]
Mend Heating, Home Heating Systems

baxi 105e and baxi 80 eco boilers will not ignite?

hi i am having problems with the above boilers, they refuse to light up. Have replaced gas valve and tested th... [Read more]
Mend Heating, Home Heating Systems

BAXI 105E Instant. System pressurising when on DHW only?

Baxi 105e instant. Diverting valve operating head keeps clicking on and off Pressure guage building up press... [Read more]