Recent: Lg vcr?

Mend Vaillant Gb 242

Free repair help

We have 61 questions about mending 'vaillant gb 242'

How to mend Vaillant Gb 242

Pages 4321
Mend boiler hot water diverter valve
1

Vaillant Turbomax VUW GB 242 E - no hot water?

CH works fine. DHW works when CH is on. No DHW when CH is off. White rocker arm isn't pushing down the mi... [Read more]
Mend Vaillant Turbomax Error
1

what code 5.1 means on vaillant turbomax vuw gb 242-5 boiler?

my boiler plays up on running my hot water, the info button lights up and upon pressing it the code 5.1 comes ... [Read more]
Mend combi boiler heat exchanger vaillant
2

leak from a vaillant combi bioler?

i have a leak from the d h w. heat exchanger i belive. it is a black 3 tubed chamber to the left of my bioler ... [Read more]
Mend boiler leaking Vaillant
3

VAILLANT COMBI BOILER GB 242 EH LEAKING?

My vaillant wall mounted combi boiler VCW GB 242 EH (GC-No.4704413) is leaking from the right hand side and t... [Read more]
Mend Vaillant Lockout Boiler
1

model VCW GB 242 EH vaillant combi boiler ignition problem?

occasionally, when the boiler ignites,the burners light and then go off, then on, then off again sometimes up ... [Read more]
Mend boiler central heating lockout
2

vaillant vcw-gb 242 eh not igniting to either heat dhw or ch?

boiler was drained to look at water valve diaphragm as central heating was not working (ie) diverter valve no... [Read more]
Mend boiler heating diverter
1

Vaillant VCW GB 242 EH no hot water?

Hi i have a problem that i have not hot water, but my central heating works fine, does it sound like i need a ... [Read more]
Mend heating radiators thermostat
1

HOW CAN I FIX MY VCW-GB-242-EH?

THE FLOW THERMOMETER IS AT ZERO SO I HAVE NO HEAT IN MY RADIATORS BUT I DO HAVE HOT WATER COMING FROM THE TA... [Read more]
Mend boiler ignition central heating
8

Vaillant VCW GB 242 EH?

I have a vaillant vcw gb 242 eh boiler that was already in my flat when i bought it, i have no idea how old it... [Read more]
Mend vaillant spark gb
3

HELP! Vaillant combi inop. No Spark VCW GB 242EH?

I have a Vaillant Combi VCW GB 242 EH and it will not ignite, No Spark, No Gas (No Voltage to Ignition Module... [Read more]
Mend Vaillant Central Heating Pressure
2

vaillant vcw gb 242 eh, not igniting?

vaillant vcw gb 242 eh? i have drained my central heating system and switched it off at the boiler, i have ... [Read more]
Mend central heating boiler system pressure
1

vaillant vcw gb 242 eh?

i have drained my central heating system and switched it off at the boiler, i have left the boiler on thinking... [Read more]
Mend boiler heating cuts out
2

Vaillant VCW GB 242 EH, cuts out when upto temp?

My Vaillant VCW 242 EH cuts out when upto temperature. When its fires first time it stays on for 2-3 minutes, ... [Read more]
Mend Vaillant Central Heating Hot Water
3

Vaillant VCW GB 242 EH?

I have a vaillant vcw gb 242 eh boiler that was already in my flat when i bought it, i have no idea how old it... [Read more]
Mend boiler replacement condensing
2

What should I replace a Vaillant VCW GB 242 EH with?

I'm thinking about replacing my Vaillant VCW GB 242 EH. To make it as easy as possible I'm trying to find out ... [Read more]
Mend boiler combi heating
4

Where can I get a manual for my Vaillant VCW GB 242 EH combi?

I have a Vaillant VCW GB 242 EH combi which is acting up. Just had a guy replace the pressure release valve fo... [Read more]
Mend heating hotwater pressure
2

no hot water?

vaillant turbomax vuw gb 242 e/282 e .the hot water is luke warm, also the hot water pressure as become very p... [Read more]
Mend vaillant combi heating
1

Vaillant Combi Boiler?

I have a leak on the Domestic side of the Boiler It is a Boiler of about 15 years old with an id plate of VCW... [Read more]
Mend boiler heating ignition
10

Vaillant VCW GB 242 EH - burner keeps burning with Heating off and DHW Off?

DHW works fine, Boiler on with tap opened, off with tap closed, but reignites after a few seconds on low flame... [Read more]
Mend boiler heating vaillant
1

vaillant VCW GB 242 EH?

My dad's VCW GB 242 EH was leaking at diaphram unit so we replaced it and also the divertor. However, the igni... [Read more]
Pages 4321

Mend Vaillant GB 242 EH

howtomendit.com find out how to mend just about anything.
Ask Question