How to mend ... Replaced Pcb Stays

Mend potterton boiler work light

Potterton?

I've just replaced pcb, 2 motorised valves, thermostar and timer ... but boiler still does not work! The light... [Read more]
Mend combi light mode

My chaffoteaux britony 100se combi fails to light in CH mode?

My Chaffoteaux Britony 100se combi fails to ignite in CH mode, it works fine in HW mode!?! When I select CH... [Read more]
Mend indesit stopped working

indesit washer/dryer w12 dryer heater stays on?

my indesit w12 washer dryer stopped working and I could smell something was getting very hot. The program swit... [Read more]
Mend boiler lights flame

boiler lights, but just ticks over, IE: it won't go to full flame?

The boiler is a Radiant RS24. It lights, but stays on tickover. We've had a new pcb, limit thermostat and heat... [Read more]
Mend baxi solo light

Baxi Solo 3 60pf?

Hi can anyone shine some light on this. Boiler on, fan comes on, pilot comes on, boiler fires. Stays on for a... [Read more]
Mend hot water switched

POTTERTON PRIMA F ERRATIC FAILURE TO IGNITE?

When the hot water or heating is switched on the boiler attempts to start up, i.e. the fan starts and stays on... [Read more]
Mend myson pilot boiler

Myson Apollo 50si?

Pilot light wasnt lighting so replaced the PCB. Now the pilot light stays on but the boiler doesn't kick in e... [Read more]
Mend replaced pcb stays

kenwood a901a?

i have replaced blown pcb but cannot get mixer to slow down.it stays constant speed fast all the time thanks.
Mend wont switch off

potterton prima f central heating won't switch off?

I've replaced the control unit and the problem persists. Hot water responds to timer etc but central heating ... [Read more]
Mend potterton pcb ago

Potterton suprima 60 - stays on all time?

My Potterton Suprima 60 ( with new PCB 3 years ago ) has developed a fault where it stays on continuously even... [Read more]
Mend replacement pcb replaced

Potterton Suprima 60 - replacement PCB Kit?

I had my Potterton Suprima 60 pcb replaced with the PCB Kit No. 5111603 18 months ago. The boiler pilot light... [Read more]
Mend worm pilot light off

Glow Worm Compact 80 P - pilot light trips off?

Initially, relay constantly clicking in and out, boiler flaming up and down; then pilot tripped out and once r... [Read more]
Mend flame boiler high

Saunier Duval SD623: Flame goes off and on when boiler is on high setting?

For the past few months the boiler flame goes off and then on repeatedly when boiler is on high stting (when h... [Read more]
Mend 40ff burner going

Glowworm Ultimate 40FF - main burner keeps going out and relighting?

The pilot lights, its continues to spark then the main burner lights then the main burner goes out after a few... [Read more]
Mend vaillant 242 temperature

Vaillant VCW GB 242 EH, cuts out when upto temp?

My Vaillant VCW 242 EH cuts out when upto temperature. When its fires first time it stays on for 2-3 minutes, ... [Read more]
Mend ch potterton puma 80

No CH with Potterton Puma 80?

I have a problem with a Potterton Puma 80 in that the CH does not appear to be working and there is no heat go... [Read more]