Pages 54321
Mend bosch bar cold
1

worcester bosch heatslave 20/25?

bar pressure rises to 3 and overflow active when cold drops back to normal 1 bar
Mend junior boiler central heating
2

How can i fix my Worcester 24i Junior combi boiler?

My boiler will not always ignite for hot water but would for central heating and the red fault light would fla... [Read more]
Mend sime format heating system
2

sime format c boiler-female in distress!!?

Hi, my heating has been off most of the summer and on swithcing the system back on it worked perfectly but i n... [Read more]
Mend pilot fan pressure
1

pilot ok ,fan ok, pressure ok but no hot water?

morning all am having probs with my swift flow 80.i had a problem with it holding pressure but after it spit ... [Read more]
Mend pressure ferroli starts
1

very hot water,high pressure and drips.....ahhhh!?

recently moved into house with ferroli modena 80e,serial starts 99. well it is a nightmare. the water in showe... [Read more]
Mend pressure central heating
3

High pressure on my Optima Ferolli 901 central heating?

Hi, I have a Ferroli optima 901 . I had problms with the DHW and foolishly adjusted this on the mod gas valve... [Read more]
Mend combi appear fine
4

Should my combi boiler come on when the cold tap is used..??

I have recently had a Glowworm combi (30cxi) installed - everything appear to be working fine, but I have noti... [Read more]
Mend boiler cold pressure bar central
7

worcester 28si II boiler?

from a cold start my worcester boiler pressure is 1 bar, but when i switch the central heating on and it warms... [Read more]
Mend puma 80 boiler
1

How can i fix my Potterton Puma 80 combination boiler?

When I turn on the hot water tap at the sink, the boiler fires up but shuts off after 5 seconds. It does the s... [Read more]
Mend shower despite changing
1

No temp control on 5th floor shower?

I live on the 5th floor of block of flats and despite changing to mixer thermostatic shower, cannot control t... [Read more]
Mend boiler control fire
3

how can i fix my baxi 130 he boiler ?

my control panel shows no fault however on fire up it will display the neon burner light as on , then a few mi... [Read more]
Mend worcester boiler hello
2

My Worcester 24CDI combi boiler leaking brown sticky fluid badly!?

Hello all, Hope someone can answer my question as I am quite concerned. I have a Worcester 24CDI combi boi... [Read more]
Mend fires off heat
2

Icon 23-t Fires up and goes off. Just runs with no heat?

Hot water works but not very hot. Icon 23-t. Heating comes on but when the radiators are warm the burner... [Read more]
Mend oil boiler fluctuating
3

Oil Boiler Pressure Gauge fluctuating?

I have had a new Worcester Bosch Oil Condensing Combi fitted (Aug 07). The installer set the red gauge at 1.5 ... [Read more]
Mend potterton boiler coming
1

Potterton combi 80 boiler?

I have re pressurised the expansion tank as suggested. There is no water coming from the valve on the unit nor... [Read more]
Mend cold bar boiler
2

cold pressure over 2.5 bar on vokera Excell 80sp?

I have a vokera Excell 80sp boiler and the pressure when the heating is cold is 2.5 bar. I think i need to re... [Read more]
Mend boiler pressure wife
4

Jaguar Boiler - F0 flashing after I bled the radiator. Loss of pressure!?

Hello all. My wife is currently not speaking to me, so I hope you can help. I have read through the answer... [Read more]
Mend Bathroom Appliances, Baths and Showers
3

How to fill up bath quicker?

A rented place we are renting at the moment is perfect bar one problem that the whole family loves baths and p... [Read more]
Mend 28 boiler pressure
15

E02 error code ariston microgenus 28?

Boiler loses pressure frequently, especially when cold, E02 code keeps coming up. After repressurising the boi... [Read more]
Mend boiler read manual
1

vokera mynute 28se pressure keeps dropping?

got vokera 28se boiler and the pressure keeps dropping ,keep on topping up system .but shouldn't have too ,fro... [Read more]