Recent: Matsui ct-111ss?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Pilot Ideas 80

Free repair help

We have 36 questions about mending 'pilot ideas 80'

How to mend ... Pilot Ideas 80

Pages 21
Mend pilot light keeps going out potterton puma 80
7

PILOT LIGHT KEEPS GOING OUT on POTTERTON PUMA 80?

Hi, Can You help me please ? The Pilot Light on my Puma 80 keeps going out. If I switch on my Central H... [Read more]
Mend potterton 80 pilot
2

Potterton RS 80 Pilot light keeps going out ?

I've just had the boiler serviced and over the last couple of weekd the pilot light has been going out more an... [Read more]
Mend not call dhw ch
1

Vokera flowmatic 20/80 not igniting on call for DHW or CH?

System was working and, on noticing temperature drop in the room found that pilot light is lit, fan is operati... [Read more]
Mend pilot ideas 80
3

My pilot light won't stay ignited - do you have any ideas what can be wrong?

I have a Vokera Excel 80 Boiler and the pilot light won't stay ignited - I have to re-ignite nearly every half... [Read more]
Mend pilot light appreciated
1

pilot light wont relight on my boiler..any help will be appreciated??

my pilot light recently stopped working on my glowworm economyplus 80(443267) boiler and it is electric igniti... [Read more]
Mend worm pilot light off
2

Glow Worm Compact 80 P - pilot light trips off?

Initially, relay constantly clicking in and out, boiler flaming up and down; then pilot tripped out and once r... [Read more]
Mend was working fine weekend
1

I have a potterton puma 80 which was working fine until the weekend?

We have a pilot light it wont fire up. We have bled the radiators at the top of the house and 1st floor and... [Read more]
Mend ch 15 hw
1

C/H lasts for 15 seconds!?

potterton puma 80, h/w is fine but when calling for c/h boiler fires and runs for approx 15 seconds then shuts... [Read more]
Mend boiler dhw days
5

Is my Fan faulty?

After having problems with my boiler not supplying any DHW or CH the last couple of days i am of the opinion i... [Read more]
Mend hot boiler vokera
5

No Hot water!?!?

Today my boiler has decided not to supply me with any hot water. It's a Vokera 20-80 R.S flowmatic, quite an o... [Read more]
Mend potterton puma 80 boiler
5

Potterton Puma 80 Boiler?

The pilot light on our boiler has gone out. We can get it to light again but it will not stay on. this has bee... [Read more]
Mend glow worm flow help
2

i have a glow worm swift flow 80 combi boiler, need help to repair?

dhw was intermittent and now i'm lucky if the heater fires up at all the pilot light is ok , i have fitted a n... [Read more]
Mend vokera excell 80 sp
6

Vokera Excell 80 SP?

When we run our shower at home, it switches between hot and cold water every 15-20 seconds or so, and has been... [Read more]
Mend pilot going potterton
1

Pilot Light Keeps Going out, Potterton Puma 80?

When the Heating has been on for a long time (4/5 Hrs), my pilot light goes out and the main burner also goes ... [Read more]
Mend boiler starts running
3

Potterton Puma 80 firing on and off?

My Potterton Puma 80 comi boiler starts firing on and off after it has been running for a few minutes - both h... [Read more]
Mend potterton going hot
1

pilot light goes out dhw potterton puma 80?

pilot light keeps going out on hot water linked out overheat stat & hot water worked fine replaced overheat st... [Read more]
Mend lights going leave
1

Potterton Puma 80 pilot extinguishes overnight?

My Puma 80 lights okay, heats up okay, but the pilot keeps going out when we leave it for a few hours. It reli... [Read more]
Mend potterton puma 80
1

Potterton puma 80 dies after a minute or two?

My eleven year old puma has ceased to suply both hw and ch, when either is required it starts up nicely but c... [Read more]
Mend 80 boiler pilot
1

Potterton Puma 80 c/h intermittently working until warmed up?

My boiler, Potterton Puma 80 (may be an 80e as no pilot light?) has been working fine for 5 years and now it t... [Read more]
Mend out after using
3

Why does the pilot on my Potterton Puma 80 goes out after using hot water?

The central heating can run for hours then if you turn the hot water tap on, you get hot water, but after the ... [Read more]
Pages 21

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question