Recent: Fix food processor motor?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Lights Central Heating

Free repair help

We have 170 questions about mending 'lights central heating'

How to mend ... Lights Central Heating

Pages 54321
Mend boiler works central

how can i fix my ariston boiler eurocombi sx20 mffice type c?

the boiler works on the central heating, but not on the hot water. it lights and then after 10 seconds goes ou... [Read more]
Mend boiler working central

boiler keeps cutting out brittony combi 80 se?

Hi my boiler is working fine when the central heating only is on but when i turn the hot water on it cuts out,... [Read more]
Mend hot water vaillant turbomax 242e

Intermittent hot water with my Vaillant TURBOmax VUW 242E?

For the past 4 months I have had intermittent hot water with my Vaillant TURBOmax VUW 242E, well rather luke w... [Read more]
Mend hot central heating ok

No Hot water Ravenheat RSF84ET, central heating OK though?

I have no hot water from my Ravenheat RSF84ET. Turning on the hot taps i don't hear the boiler trying to ligh... [Read more]
Mend hello problems basically

Worcester 24i - Cold Radiators!!!?

Hello I am having problems with my central heating system. Basically the radiators are cold even when the hea... [Read more]
Mend heating water lights

Please Help me to fix my Myson Appollo Boiler?

when central heating or hot water is put on it lights as per normal,after 2 or 3 minutes it starts banging and... [Read more]
Mend help broken switch

Help!!! Ideal isar HE boiler not working at all?

hi well a few days ago my isar He boiler has seemed to have broken down 1)it does not switch on 2)if the po... [Read more]
Mend boiler weeks hot

how can i fix my modena ferroli 80E boiler?

twelve weeks ago, my central heating and hot water stopped wrking, i had to move out and stay with friends as ... [Read more]
Mend heating burner going

Vokera 12_24 RSE Mynute Central Heating Boiler Burner keeps going out?

I have a Vokera 12-24 RSE Mynute Heating Boiler(Direct System)When the room thermostat calls for heat the pump... [Read more]
Mend water central heating working boiler

vokera maxim 24, hot water ?

central heating is working ok but on hot water the boiler cuts out then lights , cuts out lights and so on, ha... [Read more]
Mend baxi hot central

Baxi SOLO, New Fitted in 1991- pilot lights but will not stay on?

The hot water and central heating system was operating as normal but then we noticed that the hot water had go... [Read more]
Mend ferroli low pressure boiler

ferroli modena 102 problem?

i have recently changed the low pressure switch on my modena 102 combi boiler, it was workin great for 2 weeks... [Read more]
Mend worm central heating working

glow worm - central heating not working as pilot burner light does not stay?

I follow the lighting instruction, but the pilot burner lights are not holding even after several attempts to ... [Read more]
Mend central heating water

Glow Worm economy plus 40F central heating problem?

We have a GW economy plus 40F boiler that is heating our water fine but when you turn the central heating ther... [Read more]
Mend timer works fine

Vokera Linear 24 timer fault?

The boiler works fine in both hot water and central heating modes until the timer is set. When the time is rea... [Read more]
Mend 40ff burner going

Glowworm Ultimate 40FF - main burner keeps going out and relighting?

The pilot lights, its continues to spark then the main burner lights then the main burner goes out after a few... [Read more]
Mend up hot doesnt ch

Boiler fires up when demand for hot water but doesn't when demand for C/H?

I have a Potterton Netaheat Profile 80e boiler, Honeywell V4073A mid-position valve, Honeywell ST699B programm... [Read more]
Mend water bath taps

valliant boiler?

hi and thanks for taking the time to answer my question.... we cannot get any hot water for bath or shower o... [Read more]
Mend could diverter turned

Could a faulty diverter valve cause lockout when the taps are turned off?

I have a potterton puma 80e. The lockout light is comming on after a shower has been taken. It lights once t... [Read more]
Mend combi cutting out problem

BAXI COMBI 105e cutting out problem?

3 year old BAXI 105e problem when DHW is selected pressure is 1.1bar all lights on except central heating.temp... [Read more]
Pages 54321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question