Recent: How do i deactivate siren on lp1-4000?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Glow Worm Boiler

Free repair help

We have 1454 questions about mending 'glow worm boiler'

How to mend Glow Worm Boiler

Mend worm boiler fire
4

what does the f 9 fault mean on the glow worm 30cx boiler?

when I turn my heating on the morning the boiler does not fire up. I sometimes have to reset the system 3 time... [Read more]
Mend worm saver help

Glow worm Space Saver 50 MK11 fault?

Please can anyone help? Boiler keeps tripping out. Pilot light stays on fine. When you turn the 'min-max' swit... [Read more]
Mend heating boiler temperature

My Glow-worm ultimate 50BF fires up ,but then goes off after a few minute?

Boiler fires up for a few minutes ,goes off then fires up again Radiators upstairs and down are warm but not ... [Read more]
Mend boiler home heating gas fire

Is it still possible to get a thermastat for a Glow Worm Majorca Two boiler?

I need a thermastat for a Glow Worm two Gas Fire/Back Boiler. Serial No 010172. Can anyone help. Thanks
Mend boiler light burner
2

boiler Make Glow Worm Micron 50 FF ?

keep cuting off with the two green light reset and burner on blinking, and it only come s on for one mins. wha... [Read more]
Mend glow worm help

Glow Worm 30ci - got hot water but no C.heating?

Firstly just like to say thanks to all that help on here. I am fairly competent with this kind of stuff, and ... [Read more]
Mend rads warm water

Glow-worm fuel saver 100 rads not getting warm enough?

when first installed water warmed very quickley then stat cut in and boiler stayed of for about 30 secs then c... [Read more]
Mend replace exchanger help
1

Need to replace the Heat Exchanger for a glow worm 38?

Can anyone help, my heat exchange has apparently cracked and is dripping water all through the electrics and f... [Read more]
Mend boiler fault code glow-worm
6

Glow-worm 30HXI F5 fault code - cannot restart boiler?

When I switch off, turn the RHS switch to 0 and the LHS switch to off and pause as instructed, it usually star... [Read more]
Mend hot water glow worm boiler heating
2

Hot water problem on Glow worm Flexicom 30cx boiler?

I have a Glow Worm Flexicom 30cx boiler. The heating is fine but when using the hot water for a shower or bath... [Read more]
Mend central boiler hot water problem
1

central heating assistance ?

the boiler ia a Glow-worm energysaver hot water seems to be the problem the boiler can be on for hours and sti... [Read more]
Mend timer switch switched

merlin boiler without water !!!?

I have left my Merlin Boiler on a timer switch whilst I was away, but I switched off the water that fed the bo... [Read more]
Mend hot water heating

Hot water but no heating?

Hi i have a fully pumped two valve system which until recently has been working reasonably well, I say reasona... [Read more]
Mend central heating runs water system
1

Central Heating. GLOW-WORM BOILER?

My Glow-worm boiler runs for a few minutes then cuts out. It heats the water but NOT the central heating syste... [Read more]
Mend glow worm boiler
1

how to fix my glow worm boiler?

my glow worm 24ci boilre keeps loosing its pressure
Mend part numbers model
1

Part numbers for the Glow Worm Fuelsaver Model 55F?

Does anyone know the part numbers for the PCB and Fan fitted to the Glow Worm Fuelsaver Boiler Model 55F?
Mend boiler fault heating home
6

Glow-worm flexicom 30cx boiler?

Can someone tell m what an F43 fault is on the Glow-worm flexicom boiler and how to fix it? No heating on in h... [Read more]
Mend boiler mins shuts

glow worm micron 50ff boiler ?

glow worm micron 50ff boiler switches on for about 20 mins then shuts off leaving the two green lights flashin... [Read more]
Mend boiler glow power

glowworm boiler wont light?

I my glow worm boiler will not light on demand i have to turn the power switch off and then back on again to g... [Read more]
Mend glow boiler indicates
4

how can i fix my combi?

my glow worm boiler is flashing f10 error code...which indicates something to do with return thermistor sensor... [Read more]

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question