Mend potterton netaheat electronic

Potterton Netaheat 6-10 electronic?

Pleas advise what might cause a fuse to blow on control unit 407676? I don't think the problem is the unit cou... [Read more]
Mend will not fire

Potterton Netaheat 16-22 will not fire up?

My Dad has a Potterton Netaheat 16-22 MK 2 F boiler . it has not bean run for a few months(prior to this worki... [Read more]
Mend potterton netaheat boiler control

No power to my potterton netaheat?

My boiler tripped a fuse and now will not power up. There are no lights on the honeywell control (ST699-B1002-... [Read more]
Mend start blows fuse

start up problem on Potterton Netaheat 407676?

I have a Potterton Netaheat 407676. As the system tries to fire up it blows the 1 amp fuse thats on the PCB c... [Read more]
Mend fan air flow

potterton netaheat 10-16?

i have replaced fan thermastat air flow switch pc board the fuse is ok but still nothing happens when i switch... [Read more]
Mend potterton 50e pilot light

Potterton Netaheat 50e Boiler?

After 9 years the pilot light has gone out and the heating and hot water have gone off. When working prope... [Read more]
Mend potterton netaheat boiler

how can i fix my potterton netaheat boiler?

I have a potterton netaheat boiler 10-16 that appearas to fire up fine but after about 5mins it seems to blow ... [Read more]
Mend potterton problem seconds

potterton netaheat Mk 11. Electrical problem?

After about 3 seconds of switching on the main fuse (1 Amp) blows.(The fans comes on straight away) I've repla... [Read more]
Mend internal fuse blow

Potterton Netaheat 16-22 mk11F?

I have a Potterton Netaheat 16-22 mk11f The internal fuse blow when switched on. Could it be the 11 pin 3 po... [Read more]
Mend spur fuse boiler

Potterton 40e Netaheat 3A Spur Fuse Blowing?

We have a Potterton 40e Boiler and it has worked fine for 6 years. In the past few week it has resorted to bl... [Read more]
Mend manual fuse main

user manual or information?

Hi, a friend has a potterton netaheat 10-16. The fuse on the main board keeps blowing. From start, everything ... [Read more]
Mend power flat start

Potterton Netaheat EP 2000?

I have a Potterton Netaheat EP2000. Recently the power in my whole flat cut itself off following the start up... [Read more]
Mend fuse potterton netaheat

Fuse (1A) blows on the PCB in the Potterton Netaheat 10-16?

The 1 amp fuse located on the PCB of the Potterton Netaheat 10-16 MKIIF blows at start up. Pressure switch se... [Read more]
Mend netaheat 10 16

how do I relight the pilot light on a potterton netaheat 10 -16?

My boiler has stopped woking and I think the pilot light went out when a fuse was tripped. How do I relight t... [Read more]
Mend time electric switch

My Potterton Netaheat boiler won't work?

The time controller in the kitchen will work when electric is switch on, both HW and HTG are put to the on pos... [Read more]