Recent: Replace rear right door upper right latch cable - high roof?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Dhw Replaced Diverter

Free repair help

We have 29 questions about mending 'dhw replaced diverter'

How to mend ... Dhw Replaced Diverter

Pages 21
Mend Heating, Home Heating Systems

how can i fix my Sime Friendly Format 100E Boiler?

When the hot water is drawn off the boiler fires up heats the water the boiler then cuts in & out so the showe... [Read more]
Mend Kitchen Appliances, Electric Cookers

How can I fix my Ravenheat RSF84ET boiler?

On my Ravenheat RSF84ET boiler I haven't any DHW. I have replaced the diverter valve & microswitch, plus I hav... [Read more]
Mend Heating, Home Heating Systems

Heating/Hot Water Problems with Ravenheat RSF100ET?

Hi Original problem was not very hot DHW, but burner running flat out. Changed both DHW and CH thermistors, ... [Read more]
Mend Heating, Home Heating Systems

ace high boiler problem?

replaced diaphram and diverter valve service kit , ch working ok , in dhw only mode both central he... [Read more]
Mend Heating, Home Heating Systems

Any more suggestions for my baxi 105e please?

woke up the other morning with no heating or hot water from my 5 or 6 year old baxi 105e combi.i have,within t... [Read more]
Mend Heating, Home Heating Systems

baxi combi 105e boiler,no heating or hot water?

woke up the other morning with no heating or hot water from my 5 or 6 year old baxi 105e combi.i have,within t... [Read more]
Mend Heating, Home Heating Systems

Hot Water Problem with Ideal Isar He24 Combi?

Hi, Can anyone help? A friend of mine is having problems with her hot water supply from her Ideal Isar He2... [Read more]
Mend Heating, Home Heating Systems

potterton performer 24kw HEcombi?

Hello ,is there any quallified heating engineers out there who may know wat this fault is. no hot water,the p... [Read more]
Mend Heating, Home Heating Systems

no hot water?

i have a ravenheat fanned combi CSI 85 A (T), i have no hot water but i have heating , i have checked and repl... [Read more]
Mend Heating, Home Heating Systems

Vokera boiler works in heating mode but not Hot water only mode?

I have a problem with my boiler it is a Vokera 20-80 RS flowmatic. The flowswitch tries to move but does not o... [Read more]
Mend Heating, Home Heating Systems

Vaillant Turbo Max Problem?

Hi, I had a classic case of a diverter valve problem. No DHW - the plastic arm wasn't engaging the micro switc... [Read more]
Mend Heating, Home Heating Systems

Vaillant TurboMax Diverter Valve problem?

I'm sick of repairing this TurboMax. First, a history of problems. The diverter valve, then a switch on th... [Read more]
Mend Heating, Home Heating Systems

Leak on Baxi 105e Combi. Boiler?

I could see it was apparently coming from what I thought was a grub screw missing that holds the DHW Pressure ... [Read more]
Mend Heating, Home Heating Systems

repair of ravenheat 820/20 fan assisted combi-boiler?

central heating is working but no dhw.lot of banging and popping recently before failure.replaced diverter val... [Read more]
Mend Heating, Home Heating Systems

how can I fix leak on combi 105e?

I have a water leak between the diverter manifold and the DHW pressure differential valve,I have replaced the ... [Read more]
Mend Heating, Home Heating Systems

Sime Friendly Format 80e, replaced diverter valve but rads. still get hot?

Boiler: Sime Friendly Format 80e Problem: Radiators get hot when DHW is run. I had assumed this was the di... [Read more]
Mend Heating, Home Heating Systems

Sime Super 90 DHW/divertor valve problems HELP!?

Just replaced the diaphragm in the diverter valve, and lubricated the spindle with silicone grease. Although t... [Read more]
Mend Heating, Home Heating Systems

Vaillant Turbomax VUW GB 242 E - no hot water?

CH works fine. DHW works when CH is on. No DHW when CH is off. White rocker arm isn't pushing down the mi... [Read more]
Mend Heating, Home Heating Systems

Vaillant Turbomax VUW242E No hot water?

I have a Vaillant Turbomax VUW242E boiler,Heating is ok but not getting any hot water. I have replaced the DH... [Read more]
Mend Heating, Home Heating Systems

Sime super 90 combi boiler, low water pressure from dhw taps?

I have just replaced the diaphram in the Diverter valve, but still have very low pressure and no running water... [Read more]
Pages 21

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question