Mend 100e hot water

how can i fix my Sime Friendly Format 100E Boiler?

When the hot water is drawn off the boiler fires up heats the water the boiler then cuts in & out so the showe... [Read more]
Mend boiler replaced avail

How can I fix my Ravenheat RSF84ET boiler?

On my Ravenheat RSF84ET boiler I haven't any DHW. I have replaced the diverter valve & microswitch, plus I hav... [Read more]
Mend water problems ravenheat

Heating/Hot Water Problems with Ravenheat RSF100ET?

Hi Original problem was not very hot DHW, but burner running flat out. Changed both DHW and CH thermistors, ... [Read more]
Mend ace high boiler problem

ace high boiler problem?

replaced diaphram and diverter valve service kit , ch working ok , in dhw only mode both central he... [Read more]
Mend 105e hot water

Any more suggestions for my baxi 105e please?

woke up the other morning with no heating or hot water from my 5 or 6 year old baxi 105e combi.i have,within t... [Read more]
Mend baxi combi 105e boiler heating hot water

baxi combi 105e boiler,no heating or hot water?

woke up the other morning with no heating or hot water from my 5 or 6 year old baxi 105e combi.i have,within t... [Read more]
Mend water isar combi help

Hot Water Problem with Ideal Isar He24 Combi?

Hi, Can anyone help? A friend of mine is having problems with her hot water supply from her Ideal Isar He2... [Read more]
Mend Heating, Home Heating Systems

potterton performer 24kw HEcombi?

Hello ,is there any quallified heating engineers out there who may know wat this fault is. no hot water,the p... [Read more]
Mend hot water 85

no hot water?

i have a ravenheat fanned combi CSI 85 A (T), i have no hot water but i have heating , i have checked and repl... [Read more]
Mend boiler works problem

Vokera boiler works in heating mode but not Hot water only mode?

I have a problem with my boiler it is a Vokera 20-80 RS flowmatic. The flowswitch tries to move but does not o... [Read more]
Mend vaillant valve dhw

Vaillant Turbo Max Problem?

Hi, I had a classic case of a diverter valve problem. No DHW - the plastic arm wasn't engaging the micro switc... [Read more]
Mend vaillant turbomax diverter valve problem

Vaillant TurboMax Diverter Valve problem?

I'm sick of repairing this TurboMax. First, a history of problems. The diverter valve, then a switch on th... [Read more]
Mend combi boiler missing

Leak on Baxi 105e Combi. Boiler?

I could see it was apparently coming from what I thought was a grub screw missing that holds the DHW Pressure ... [Read more]
Mend central heating working

repair of ravenheat 820/20 fan assisted combi-boiler?

central heating is working but no dhw.lot of banging and popping recently before failure.replaced diverter val... [Read more]
Mend leak combi 105e

how can I fix leak on combi 105e?

I have a water leak between the diverter manifold and the DHW pressure differential valve,I have replaced the ... [Read more]
Mend replaced rads boiler

Sime Friendly Format 80e, replaced diverter valve but rads. still get hot?

Boiler: Sime Friendly Format 80e Problem: Radiators get hot when DHW is run. I had assumed this was the di... [Read more]
Mend problems help replaced

Sime Super 90 DHW/divertor valve problems HELP!?

Just replaced the diaphragm in the diverter valve, and lubricated the spindle with silicone grease. Although t... [Read more]
Mend vaillant turbomax 242

Vaillant Turbomax VUW GB 242 E - no hot water?

CH works fine. DHW works when CH is on. No DHW when CH is off. White rocker arm isn't pushing down the mi... [Read more]
Mend water micro switch

Vaillant Turbomax VUW242E No hot water?

I have a Vaillant Turbomax VUW242E boiler,Heating is ok but not getting any hot water. I have replaced the DH... [Read more]
Mend low pressure taps

Sime super 90 combi boiler, low water pressure from dhw taps?

I have just replaced the diaphram in the Diverter valve, but still have very low pressure and no running water... [Read more]