Recent: Fix food processor motor?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Ch Set Off

Free repair help

We have 117 questions about mending 'ch set off'

How to mend ... Ch Set Off

Pages 65432
Mend drayton broken appreciate

How can I fix my actuator?

I suspect that the actuator on the motorised valve (BGMVSP-23, aka Drayton MA1) is broken and would appreciate... [Read more]
Mend starts hw ch

Potterton Profile 80E Starts OK on HW but not on CH?

Boiler would start (fan running for 20 seconds) but would not complete the ignition cycle. Replaced the PCB. A... [Read more]
Mend problem turned set

radiator problem with powermax he?

The radiators get hot when the ch. is turned on or off with the roomstat set low but the dhw. is turned on. W... [Read more]
Mend burner fires ch

Burner fires up and CH comes on, even though not selected at switch ?

Having been impressed with the diaphragm solution I was given here in 2010, I have another problem now with my... [Read more]
Mend boiler dhw hot water

Boiler set for DHW only,but CH also comes on Ferroli optima 1001?

The boiler is set for DHW only, recently even when hot water is not on demand , boiler switches itself on for ... [Read more]
Mend he july 2009

Potterton FSB HE 30 new July 2009?

Have a howling noise after firing up of boiler. Have had 4 visits from BG...1 new fan fitted, no joy. Also on ... [Read more]
Mend turn boiler set

ideal isarhe24 dhw works ch doesnt ?

i turn boiler off at night &back on a.m thermo set to manual. pressure between 2&3
Mend baxi solo not

Baxi Solo 3 heats water but not CH?

My 5 year-old Baxi Solo 3 CH circuit has just packed up, although the water heating is fine. The CH is control... [Read more]
Mend ferroli water boiler

Ferroli optimax he 38 c filling kit connections?

I topped up the water on my boiler, but think I have moved one or more of the other 3 "taps" that make up the ... [Read more]
Mend ch start heating

how do I get ch to start heating?

System:potterton kingfisher2; drayton digistat RF and potterton EP2000 controller connected via a Salamander b... [Read more]
Mend worcester greenstar boiler

Worcester Greenstar 24i junior: doesn't work!?

Hi I've just moved into a new property, the boiler is only about 2 years old; when I moved into this house th... [Read more]
Mend potterton ep2000 ch

What should I do about Potterton EP2000 programmer?

This has been perfect for the last 19 years. The HW is still perfect. The CH has developed the following fault... [Read more]
Mend boiler set potterton

Boiler cuts out when CH set to on?

I have a potterton system with a 2002 timing controler and a PT2 remote electronic thermostat. If the system i... [Read more]
Mend Heating, Home Heating Systems

how can i fix my timer & selector switches on my Thorn EMI M30/42B boiler?

I have a Thorn EMI freestanding boiler model number M30/42B and the Timer Switch does not move or set any time... [Read more]
Mend help turn turned reset

can anybody help turn on my heating?

my boilers turned on but the programmer just has dashes on it tried everything to get it on, including leaving... [Read more]
Mend glowworm boiler pressure

GlowWorm 24ci boiler high pressure fault?

With the boiler left on, i.e. no demand for DHW or CH, the pressure will remain constant, set at 1.0 bar. Whe... [Read more]
Mend operate water problem

ch will not operate. hot water no problem?

hot water no problem ch not operating room stat set at 30C 3 port valve opened manually ch on overide ch ... [Read more]
Mend brown problem coming

potterton EP2000 (old brown one) problem - CH always on ???

I have a Potterton EP2000 - problem is when i try to put the HW slider on any setting i.e twice/ once/ 24hrs, ... [Read more]
Mend 80e call heat

Netaheat Profile 80e not lighting when call for heat?

I have a 20 year old Potterton Netaheat Profile 80e. Boiler heating water OK all summer. Wanted CH on today ... [Read more]
Mend hot after expansion vessel

Vokera Linea Max - hot cycling after re pressurising expansion vessel?

I have re pressurised the expansion vessel to 12psi having isolated and drained the boiler. The vessel now hol... [Read more]
Pages 65432

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question