Mend Drayton MA1 Actuator Valve Heating

How can I fix my actuator?

I suspect that the actuator on the motorised valve (BGMVSP-23, aka Drayton MA1) is broken and would appreciate some help on what to do next.

When central heating (CH) is turned on at the timer (and room thermostat is set), the manual lever on the actuator is in the H position. However, when I then turn on the hot water (HW) as well, the manual lever moves ever so slightly but never at the mid-position. When I only turn HW on, the lever doesn't move any further and is stuck, so doesn't move towards W position. I tried manually moving the lever, but it doesn't seem to budge. I'm guessing that my room and cylinder thermostat are working fine (heating works and I get hot water from cylinder if I heat it using backup electrical supply), so I'm guessing the actuator head rather than valve is not working?

I have subsequently removed the actuator head and began dismantling it as I thought the motor is not working. However, when I tried to disconnect the old motor, the pins on the PCB (or whatever you call it) came off the solder joint so now my actuator definitely doesn't work. How do I now know for sure the motor is working/broken? I'd rather fix a faulty motor rather than forking out on a new actuator if possible. When I removed the motor, the lever could be moved from side to side and always sprung back to the W position, I guess this is normal? Even when gears on motor is in place (but motor not connected because of the faulty wiring), I can move the lever from side to side and hear the gears moving.

I've used a pair of pliers and applied some 3-in-1 onto the valve shaft and managed to move it to the W position, so when HW is on, I only get HW through. However, when I connect it back to the valve, I can only move the lever as far as the mid-position so never all the way to H position. Obviously I can't change the valve lever through the actuator now.

Thanks in advance for any advice you are able to provide.

IW
May 2012

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Actuator Valve Heating

Related Questions ...

Mend pressure condensing boiler
3

No heating or hot water due to low pressure?

My Sabre HE condensing combi boiler keeps cutting out so I have no heating or hot water. I have to keep pushin... [Read more]
Mend boiler heating fault
2

Potterton Performa 24 DHW issues?

My Potterton Performa 24 has developed a DHW fault, & I need help resolving it please. In November, it stoppe... [Read more]
Mend central heating radiators thermostat
2

Mid Position Valve (Drayton)?

Hi, My problem is with my central heating and hot water system. This is a long one! When I select just h... [Read more]
Mend boiler central heating fault code
1

Ferroli Otimax HE38C?

Boiler has hot water, will fire up on Eco, it has everything calling for central heating and shows no fault co... [Read more]
Mend central heating hot water valve fault
1

Mid way valve fault??

I currently have hot water but no central heating When I move the 3 way valve to the H position manually the ... [Read more]
Mend boiler thermostat heating
1

Baxi Solo 3 heats water but not CH?

My 5 year-old Baxi Solo 3 CH circuit has just packed up, although the water heating is fine. The CH is control... [Read more]
Mend problem heating drayton
3

intermittent problem with central heating valve not opening?

We have a Drayton wireless for our central heating, and a Drayton ZA5679-2 2 Port motorised valve also for hea... [Read more]
Mend combi heat exchanger flow rate
7

Hot Water Problem with Ideal Isar He24 Combi?

Hi, Can anyone help? A friend of mine is having problems with her hot water supply from her Ideal Isar He2... [Read more]
Mend heating position valve
2

Is my lack of centreal heating the fault of the BGMVSP-23?

I have the above mid position valve which seems to be operating in reverse. With the motor out of the unit, i... [Read more]
Mend boiler central heating diverter valve
4

How Can I Fix A Potterton EP2002 Heating System?

My daughter has a Potterton EP2002 system with a Potterton Suprima 40L boiler and a MPE322 diverter valve. Th... [Read more]
Mend central heating hot water boiler
10

Potterton Promax 24HE - No Central Heating?

Since the weather turned colder a couple of weeks ago we have been unable to have heating without the hot wate... [Read more]
Mend heating engineer problems
1

Potterton powermax he85 problems?

Hi! Ive been having a few probs with my boiler. when i run the hot tap with my heating set to off and water... [Read more]
Mend heating will not come
3

heating will not come on?

my spacesaver 38 has been working fine for years but the last 2 months or so it has not been heating the radia... [Read more]
Mend actuator heating valve
1

not going to mid position on valve?

when I replaced the actuator on the mid position valve and controler I found that I could get heating and i co... [Read more]
Mend failing water combi
4

Failing hot water on a Saunier Duval F30E Themaclassic combi?

I have a 4 yr old Saunier F30E standard combi running on natural gas and the hot water is failing dismally. Ho... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...