Recent: Fix food processor motor?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Ch Not Working

Free repair help

We have 248 questions about mending 'ch not working'

How to mend ... Ch Not Working

Pages 131211109
Mend drayton broken appreciate

How can I fix my actuator?

I suspect that the actuator on the motorised valve (BGMVSP-23, aka Drayton MA1) is broken and would appreciate... [Read more]
Mend ch working dhw

ravenheat ?

2003 LS100 CH working ok! ask for DHW the pipe from the 3 way valve up to the heat exchanger gets very hot wit... [Read more]
Mend hot water ch normal

No Hot Water But CH is normal???

My Vokera Linea 735 boiler isn't heating up the hot water but the central heating is working perfectly. There... [Read more]
Mend help hot works fine

ravenheat csi85 combi read this it will help many!?

I have a ravenheat csi85 boiler, the hot water works fine. The central heating started switching on /off, it w... [Read more]
Mend worcester central heating water

My Worcester Greenstar 37cdi central heating won't come onot wate?

My Worcester Greenstar 37cdi central heating won't come on. The hot water is working. The Digistat sender sho... [Read more]
Mend boiler not firing

Ravenheat 84E boiler not firing up?

Hi can anyone help boiler is not firing up with ch or hw fan working , pump working pilot is sparking and has ... [Read more]
Mend ch working dhw

100e ch not working dhw ok?

ravenheat 100e has hot water no ch has water pressure & stat clicks has had varius new parts in past help pls
Mend halstead ace combi boiler

how can i fix my halstead ace combi boiler?

Hi I have a problem in my boiler.CH works very well , but when I open hot water tap burner working for 20secon... [Read more]
Mend worcester hot working

Worcester oil boiler; hot water on CH off, but CH keeps working?

I have a Worcester Heatslave oil boiler. the HW is on constant but when it kicks in to warm up the water, t... [Read more]
Mend fires switch replaced

My boiler pump runs continuously and fires even when timer switch is off?

The zone valves have been replaced but boiler still fires after the CH and HW is switched off and the over run... [Read more]
Mend replace cooker switch

How to replace control panel on Electrolux cooker hood CH 950X?

The control panel or Switch has just gone behind in the cavity. how to access it. the Panel is working and can... [Read more]
Mend worcester combi heating

how do i refill worcester 532/i combi boiler?

came back of holiday notice 3 radiators not heating bled all the air out now boiler is not working tried reple... [Read more]
Mend both central heating hot water not working

both my Central Heating and Hot Water not working?

Hi, I tried to reset my boiler but now it wont work at all. I cant get either HW or CH. plz help
Mend replaced problem fuse

Baxi Combi 133 HE Plus replaced PCB but no CH?

Hi, Problem started when fuse has gone on PCB. I have replaced PCB with new item. Hot water is working but... [Read more]
Mend problem pressure works

What is problem with Pressure on Vaillant Boiler?

I have a Vaillant Eco Tec Plus Combi boiler (5 yrs old) that works fine -but- I notice that the water pressure... [Read more]
Mend potterton not working

Potterton Ep3000 timer not working?

I have a Potterton EP3000 and the CH & HW in airing cupboard & the switches no longer seem to be working. Disp... [Read more]
Mend working button checked fuse

RE: CH Not working plus select button not working on potterton EP2001?

Hi Guys I have checked the main fuse and it is ok, By the way the CH always comes on with the HW and the HW co... [Read more]
Mend working select switch

CH Not working plus select button not working on potterton EP2001?

Trip switch went on electricity, since then CH not working and the select button option for CH also not workin... [Read more]
Mend ch sensor problem

CH sensor problem?

hi I have baxi 35/60.the boiler is indicating fault on centralheating sensor. when it turns on, its working fo... [Read more]
Mend timer unit stopped

Timer to Randall 4033 CH Control Unit Stopped?

The programming of my CH and HW system is controlled by a Randall/Danfoss 4033 unit. I know that being an ana... [Read more]
Pages 131211109

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question