Pages 4321
Mend heating burner going
1

Vokera 12_24 RSE Mynute Central Heating Boiler Burner keeps going out?

I have a Vokera 12-24 RSE Mynute Heating Boiler(Direct System)When the room thermostat calls for heat the pump... [Read more]
Mend heating boiler appears
3

How can I fix my Ideal Classic FF250 central heating boiler?

Hi, We have an Ideal Claassic FF250 central heating boiler that appears to trip our RCD, leaving us with no e... [Read more]
Mend worcester boiler water
2

Overheat cut out worcester 9.24 electronic boiler?

Had no central heating but hot water ok, boiler shuts down after 2 mins, found (eventualy) that the thermocoup... [Read more]
Mend upstairs warm heating
1

baxi solo wm 50/rs upstairs rads only getting warm?

I have flushed central heating system out. when boiler fires up it stays lit for about 1 min then stops, light... [Read more]
Mend central heating pump after boiler
1

Central heating pump continues 30 mins after boiler stops?

We have a Potterton EP3001 control panel. Problem is that when the air/water temperature is reached the pump k... [Read more]
Mend glow central heating
2

Glow Work Micro?

Due to a leak I recently had to drain the central heating system. I tied the ballcock up, to drain the system... [Read more]
Mend boiler dhw days
5

Is my Fan faulty?

After having problems with my boiler not supplying any DHW or CH the last couple of days i am of the opinion i... [Read more]
Mend Heating, Home Heating Systems
1

Pipework Mix Up?

Hi there I recently relocated some pipework so that I could fit more ceiling joists to reinforce our loft conv... [Read more]
Mend change central heating boiler
4

change of central heating boiler?

My Potterton Electronic neataheat 16-22 has to be changed as spares are scarce according to the service engine... [Read more]
Mend heat ch boiler
2

vaillant vcw-gb 242 eh not igniting to either heat dhw or ch?

boiler was drained to look at water valve diaphragm as central heating was not working (ie) diverter valve no... [Read more]
Mend central heating valve
4

central heating valve?

can any one help ,updated heating controls for seperate control of heat/water there is a isolating valve on a ... [Read more]
Mend boiler heating hot water not radiators
1

My boiler is heating the hot water but not the radiators?

I have a Glow-worm conventional boiler but at the moment the boiler is heating the hot water but not the centr... [Read more]
Mend classic ff heating boiler
1

Ideal Classic FF 260 central heating boiler?

The boiler strikes normally but after 5-6 minutes switches off, in just central heating and just hot water mod... [Read more]
Mend baxi 105e flame
4

baxi 105e flame problems?

i can get domestic hot water from the tapes, but when i turn the central heating on, the boiler goes through a... [Read more]
Mend potterton boiler out
2

Potterton c/heating boiler keeps cutting out?

i have a potterton boiler coupled with an indirect central heating hot water tank, every couple of days i hea... [Read more]
Mend central boiler started
1

What is wrong with my Potterton Kingfisher 2?

My Potterton Kingfisher 2 floor standing gas-fired Central Heating boiler has started to make a very odd noise... [Read more]
Mend model problem boiler
1

Glow-worm Ultimate?

Dear Sir/Madam, Re: Glow-warm Model No. Ultimate. I am writing to you to get more information with reg... [Read more]
Mend switched diverter valve
3

Puma 80 overheats and shutsdown when DHW switched off?

This 8 year old Potterton Puma 80 has had first a new diverter valve fitted, and now a circuit board, but stil... [Read more]
Mend puma 80 boiler heating
1

Potterton Puma 80 combi boiler hi press problems?

When Central heating turned on from cold my system has an initial hi press surge (1-3.5bar), after header temp... [Read more]
Mend central heating combi boiler
1

NO central heating from combi boiler?

Hi hope someone can help, my combination boiler Ideal stelrad/Sprint will not stay fired up when selecting cen... [Read more]