Recent: Safely remove screen protector from a Macbook Air?

Mend > Home Heating Systems

Mend Boiler Radiators Heating Controls

central heating valve?

can any one help ,updated heating controls for seperate control of heat/water there is a isolating valve on a pipe coming from the bottom of the hot water cyclinder going to the 22mm pipe just above the water pump but below the mid position valve not sure if this valve should be open or shut .
when open all works well except the last 2 radiators ie, dining/frontroom, dont get very warm but if i close the valve all the rads get hot after about 25 minutes and then the boiler shuts down and it will only allow me control of hotwater until the next day . all the controls are new and the old programer use to have hotwater only/ heating/water together am i right in thinking this is a y plan system and can anybody tell me if the valve should be open/shut and what the hell its used for cheers
ps. can send photos but need your email address because cant work out how to post pics on forum . dave

dave
April 2007
NEDS 2 B OPEN DONT HAVE PICS BUT TRY BLEEDING RADS THAT R NOT WORKING PROPERLY !!!!!!!!

DAVE
May 2007
a better answer may be to swap it for an automatic bypass valve, then you wouldnt have to adjust it so finely for balancing heating/hot water because it does it all itself.

gtheak
April 2007
send some pics hispecplumbing@yahoo.co.uk

hi-spec plumbing
April 2007
I THINK (note THINK) that this valve is to balance the system when the Y plan is open for both curcuits.

If the valve is closed it will 100% be heating only. If open the water will obviously find the shortest route,and may prefer the hot tapwater as opposed heating the rads.

I think you will have to carefully use this to balance the system water : rads.

Steve
April 2007

Related Questions ...

Mend boiler heating thermostat
1

combi oil Worcester greenstar heatslave 12/18 switches off?

I have a internal combi oil Worcester greenstar heatslave 12/18 Its has a built programmer and Hot water t... [Read more]
Mend central heating radiators hot water
1

heat water up in boiler keep flowing into radiators?

potterton suprima. put central heating on to heat up water in tank but in less than half an hour hot water s... [Read more]
Mend vaillant ecotec fault code
4

Vaillant Ecotec plus 824 with no central heating?

Please help!! We've been in this house for almost a year - so I'm not sure when the boiler was installed bu... [Read more]
Mend central heating radiators thermostat
1

Why re the upstairs radiators warm when only the hot water, NOT the heating?

Our boiler provides either hot water, or central heating, or both. Since a new radiator was fitted upstairs, w... [Read more]
Mend boiler heating thermostat
2

Potterton Netaheat Boiler stopped working?

Hello, I have a Potterton Netaheat Boiler with Potterton EP2002 Controls and Honeywell Thermostat. Last night... [Read more]
Mend boiler radiators home heating systems
2

heating glowworm 30cxi?

3ocxi will not shut off even when all controls are not calling for heat and radiators are still getting hot ev... [Read more]
Mend boiler temperature controls
1

how can i fix my Main Combi 24HE c/heating thermostat?

Hi whenever i put the heating on, the radiators will be very hot regardless if i turn the thermostat knob down... [Read more]
Mend central heating hot water potterton
5

Boiler Problem?

I have a Glow-Worm Ultimate 120FF central heating boiler that stopped working last week. Under my Direct Line ... [Read more]
Mend heating timer honeywell
1

Phantom Boiler Operation at Night!?

I have a Potterton Profile 80E Boiler servicing my hot water and central heating. My timer system is Honeywel... [Read more]
Mend central heating pressure diverter valve
6

Potterton proforma 28i?

This boiler was in the property when we moved in 3 years ago. The only controls we have are a programmer in t... [Read more]
Mend combi boiler central heating faulty
2

how to fix my vaillant turbomax plus 282/2e combi?

re: vaillant turbomax plus 282/2e combi boiler. Problem with c.h coming on when internal timer in 'off' and ro... [Read more]
Mend boiler heating radiators
2

Remeha RF boiler constantly on heating up the radiators?

I've had a new Remeha RF boiler installed in April 2008 and everything has been fine for a few months. In t... [Read more]
Mend boiler heating safety
4

ariston boiler - dangerous? Turn off heating?

My Ariston boiler heats water on demand and central heating. The boiler keeps coming on and heating up the ra... [Read more]
Mend combi boiler heating hot water
1

Combi boiler heating switched off but rads warm?

Just had a new combi boiler fitted .........when the heating is switched off the radiators are warm !!!!! The... [Read more]
Mend radiators heat central heating
1

The radiators won't heat up?

The pilot light on the gas central heating is lit but when you press the button that gets the radiators to hea... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...