Mend heating even off position
1

Baxi 80E heating is on constantly even with timer switch in off position?

Central heating pump is constantly running. Boiler lights up intermittently, runs for few seconds, then flame ... [Read more]
Mend air pressure switch
2

Air pressure switch?

air pressure switch problem i think but any advise would be greatful. When both air tube (red/white) are conne... [Read more]
Mend not changing over
4

baxi 105e not changing over to central heating?

boiler appears to be stuck on hot water even though central heating his selected and time clock and thermostat... [Read more]
Mend potterton 80e boiler switch
1

Potterton 80e boiler air pressure switch is tripping out?

My 14 year old Potterton 80e boiler air pressure switch is tripping out every 3-4 days due to water (I assume ... [Read more]
Mend boiler keeps cutting out
1

Boiler Keeps Cutting Out?

Hi I Have A Oil Boiler & A Riello Burner, When I Switch The System On It Runs For About 10-15 Mins And Cuts ... [Read more]
Mend worcester junior boiler
3

what is problem with my, Worcester 28i junior boiler?

the pressure dropped and the reset lamp was flashing. Toppd up pressure withloop to 1.5~ 2 bar and reset. boil... [Read more]
Mend help flue time
3

broken down Britony flexiflue boiler?

I previously asked for some help on my Britony flexi flue boiler the symptons are, for some time now I have on... [Read more]
Mend problems boiler heating
2

How can i fix my ferrolli 77ff combi?

having problems with a ferrolli 77ff. Boiler will not start in hot water or heating mode, fan runs. have chan... [Read more]
Mend ariston micro genus he boiler
3

how to fix Ariston Micro Genus H.E. Boiler?

hi code E 34 comes up on my ariston micro genus H.E. boiler it says in booklet -air pressure switch does not ... [Read more]
Mend turning itself off
2

My Glowworm Ulti.120FF,is continuously turning itself on and off?

The boiler fires up and runs ok for about a minute,before it starts to switch off and then reignite,this happe... [Read more]
Mend boiler fire light flame
3

potterton Performer 24 is faulty?

My potterton boiler will not fire up the red light comes on stating no flame, have replaced the Pcb card with ... [Read more]
Mend boiler stat demand
7

How do I fix my Potterton Netaheat MkIIF 16-22?

My boiler starts it's cycle on room stat demand. The internal fan runs, the pilot ignites, after 20 secs the m... [Read more]
Mend starts runs spark
2

vaillant 242 help!?

boiler starts sequence fan runs then goes to lockout,no spark at electrode,no gas getting through,have cleaned... [Read more]
Mend turbo combi boiler problem
3

valliant turbo max combi boiler problem?

Two problems. I had a refit in my kitchen the controller for the boiler's wires got pulled out. What goes w... [Read more]
Mend problem combi hot water red
2

problem with biasi 24s boiler combi?

my boiler let me run hot water off for awhile then it would go on lock out and red light come on, press to res... [Read more]
Mend boiler flow problem
1

76 boiler, air flow problem?

I have changed the airflow switch, fan runs, if i suck the airflow pipe it lights,,,,,help
Mend potterton suprima boiler
4

relating to potterton suprima 30 boiler?

The boiler runs fine but after about 3 to 5 mins unfortunately then stops (power and lights still on). It can... [Read more]
Mend boiler dhw days
5

Is my Fan faulty?

After having problems with my boiler not supplying any DHW or CH the last couple of days i am of the opinion i... [Read more]
Mend water boiler coming night
2

boiler,benchmark vented water heating system?

my boiler runs on economy seven but its not coming on at night when its suppose to . to heat water up .it came... [Read more]
Mend boiler switch runs
1

glow worm ultimate 40ff boiler won,t swith off?

My boiler will not switch off it runs constantly even though the programmer is set to off and the room stat is... [Read more]