Pages 65432
Mend vokera engineer boiler

Faulty vokera compact 25?

I have spoken to the gas safe engineer that installed this boiler new approx. 3 years ago about the problems i... [Read more]
Mend combi pressure drop

c+m se80 britony combi pressure drop?

have had this combi for about 7yrs and have had the pcb replaced 3 times. It now drops its pressure on the gau... [Read more]
Mend ideal hot water wonder

Ideal Classic no heating but have hot water?

HI all, i have just found this fabulous site, I wonder if anyone could help as right now things are just miser... [Read more]
Mend pilot thermocouple hello flame

Pilot goes out despite replacing thermocouple?

Hello, in my TA 20/30 the pilot goes out when the main flame is switched off by the thermostat. I have replace... [Read more]
Mend boiler problem hot switched

Motorised valve for boiler?

I have a problem with my boiler- i only get hot water when the CH is switched on - i think the problem is with... [Read more]
Mend replaced heating coming

How can I fix my heater?

Hi I have just received / replaced the capacitor in my Drayton heating system and now I don't get any lights c... [Read more]
Mend pressure going replaced

Biasi boiler high pressure problem?

I have a Biasi GARDA HE M96.28SM/B2 (combi) that keeps going to high pressure. I have replaced the expansion v... [Read more]
Mend timer stopped working

Randall 102 timer, my heating did not come on this morning please help?

My heating has suddenly stopped working. I have a back boiler system that has a Randall 102 timer on it. I rep... [Read more]
Mend 30 problem heat

glowworm betacom 30 problem?

Hello folks, boiler is 2 years old, had plate heat exchanger cleaned/changed/cleaned...dhw sensor replace... [Read more]
Mend 2000 hot water

How can I fix my Baxi Solo 3 PFL 40?

Baxi Solo 3 PFL 40 connected to Boilermate 2000 system.No hot water or heating,no hot water stored in Boilerma... [Read more]
Mend boiler bolier years

do i need replacement part or new boiler?

i have a vaillant combi bolier ref no vuw242 I have had this for about 12 years and now have a leak the water ... [Read more]
Mend error code week

Ravenheat CSI 120 error code 04?

I have a Ravenheat CSI 120 on which I recently (last week) replaced the diaphragm in the diverter valve. I the... [Read more]