Connecting new external sounder to Optima XM6 alarm panel?

Hi - I have purchased an Odyssey Series external sounder to replace a faulty sounder box connected to my Optima XM6 alarm panel. The terminals in the alarm panel are marked -

Strobe +,
Strobe -,
'T' Tamper Return,
'A' 0 volts,
'D' 12v +ve,
'B' Trigger on.

Many thanks.

Alan.on m

Alan Vickers
February 2007
bell box connection panel connection
A goes to terminal D 12v supply voltage
B goes to terminal B 0v trigger in alarm
C goes to terminal T tamper return
D goes to terminal A 0v supply voltage
S goes to terminal - of the strobe terminal

Chris AXIS Fire & Security
March 2007
Thanks pete. I already have the wire colours as connected to the Optima XM6 alarm box. What I need is what are the corresponding terminals on the Odyssey External sounder to connect them to.

Alan.

Alan Vickers
February 2007
you will need to see which wires are used for each function on the old box.
Wire colours are not made obvious in alarms , ie red is seldom +ve, black is seldom -ve (or 0v), its usually a random thing for added security.

Pete
February 2007
Mend Security Systems, Home Alarm Systems
Click here to mend Optima XM6 home alarm systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.

Related Categories

Mend Car Alarm Systems
Car Alarm Systems

Mend Security Systems, Home Alarm Systems
Click here to mend Optima XM6 home alarm systems