Mend Danfoss Valves Ch Hw

Diverter valves?

C/H & H/w. What a set up!!!!.

Emerging from the floor 22mm pipe which carries the pump. Continuing the 22mm on pump flow is a T off 15mm to a gate valve then changes to 22mm in to the h/w tank bottom 1/4 of side which I assume is the tank coil inlet.
Continuing further up the pump flow pipe is a 22m T off with what appears a diverter valve [has little window in it but can't see what's in it because of position] then 22mm disapears back into the floor.

Then the pump flow 22mm contunues with what again appears to be a diverter valve case has Sunvic on it no window on this one, then on to the tank two thirds up side which i assume is the tank coil return.
The hot water outlet to all taps with combined vent pipe at top of tank of course, the vent overhanging the loft cold water storage tank.
What is this system ? never seen anything like it.
We live in a bungalow so not gravity fed system.

There is also a red pump danfoss [wrong one apparently] that seems to feed a seperate hot water system, the tank side of the pipe is hot with the other side flow out cold have no idea what it feeds or fed the pump is not working no power to the cable even though its in the terminal block all wires go into from the temp: unit on tank and the two valves.
Thanks to all who bother reading this hopefully its understandable.

Charlie
October 2010
If you're looking back in carefree
'Thanks' gives some idea now what's what. I was having a little trouble deciphering what's covered and what's not covered on my c/h service contract I now have a bit of ammunition incase I get 'Sorry that's not covered'.

Charlie
October 2010
From the description (from what I can decipher), it sounds like an 'S' plan system (two zone valves rather than a diverter valve).
It is a fully pumped system, but I can never understand why 'S' plan was used rather than the diverter 'Y' plan system, it's just one more valve to go wrong imo.

Hope this helps

Carefree
October 2010

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Valves Ch Hw

Mend Heating, Home Heating Systems
Mend repair fix Danfoss home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Danfoss home heating systems