Recent: Throttle issue?

Mend Chaffoteaux Combi SE 80 Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Free repair help for Chaffoteaux Combi SE 80 home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Britony combi SE 80 by Chaffoteaux & Maury error 40/80 but CH pressure ok?

Britony combi SE 80 Boiler by Chaffoteaux & Maury,
i have the 40/80 "low waterpressure in CH circuit", but i have toped up the system to 2bar.
it has remainded at a constant pressure ie no leaks
also when drained the dial goes down to zero so gauge seems to work,
has anyone had to sort this problem out before.
thanks for any assistance

Martin
November 2009
water pressure switch is blocked or has failed and will need replacing

Dean
June 2010
sounds like dirt blocking the pressure sensor in the boiler you need to drain boiler remove sensor and clean make sure that no dirt in pipe were sensor fits if this do`s not work replace sensor

Joseph Smith
November 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Britony Combi 80 Chaffoteaux

Mend Heating, Home Heating Systems
Free repair help for Chaffoteaux Combi SE 80 home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Chaffoteaux Combi SE 80 home heating systems