aquatronic 3 shower temperature intermitant?

when shower is initially turned on you get a normal temperature. after that you have to turn the temperature switch up to 8/9 to get a decent temperature but with the sacrifice of a decent shower jet. i have removed the head and de-scaled it. i have opebed the cover and the heater element seems normal.

john powell
November 2009
There are 2 heater elements in Triton showers activated via microswitches.I have had recurrent problems with these switches overheating and so failing.If one switch is failing , which is usually the case then only one heater element is activated so you have to reduce the water flow to get warm enough water. When the switches first start to fail the problem can appear intermittently. It is usually obvious by looking at the switches if there is an overhaeting problem. The microswitches are readily available.

rowan
November 2009

Automatic Answer

We may have found other answers which could help you.

Click here for 3 Shower Temperature

Related Questions ...

Mend unit switched shower
1

No water following through the unit when switched on at the shower?

I have a digital quartz exposed shower QZ.A2.EV.05 shower, the problem initially was the temperature of the wa... [Read more]
Mend temperature water pressure bathroom
1

Mira Sport Shower boiling then cold cycle?

Hi, Yesterday my Mira Sport shower went boiling, then freezing in 60s cycles, 3 or 4 times. Then it just st... [Read more]
Mend shower temperature bathroom
1

T90i Shower?

water too hot even on number 3 on temperature dial?
Mend pressure temperature plumber
1

Shower pressure and temperature changes?

The water pressure and or temperature of the water in my shower changes completely unexpectedly and with no ot... [Read more]
Mend wondering problem time
1

Intermittent Power Shower?

Hi Was wondering if you could help? Have had a power shower problem for some time now and was browsing this ... [Read more]
Mend shower works fine water
1

mira shower hot/cold problems?

We have an old Mira 915b shower which works fine for @ 3 mins but then the hot water takes over and you cannot... [Read more]
Mend pressure temperature valve
1

Mira Advance Shower - sudden increase in pressure?

Mira Advance Shower - sudden increase in pressure.? We had a Mira shower installed in 2002. It worked fine fo... [Read more]
Mend pressure temperature valve
1

Mira Advance Shower - sudden increase in pressure?

We had a Mira shower installed in 2002. It worked fine for some years but then it was noticed that, on some oc... [Read more]
Mend shower water power
3

how can i fix my Aquatronic 3+ shower?

The main fuse into my house recently blew, when it did go somebody was in the shower, (it was brought from wic... [Read more]
Mend temperature boiler pressure
1

How can i un-jam a temperature control on a triton Hp combi shower?

The combi boiler is still working fine, and hot water is coming from my taps, but the shower has all of a sudd... [Read more]
Mend installed working perfectly
1

Why does my Mira Sport 10.8Kw shower keep tripping on High?

I have a Mira Sport shower rated at 10.8Kw which has been installed and working perfectly for 3 years. it has ... [Read more]
Mend model water coming
1

How can I repair my Aquatronic 3 electric shower?

My Aquatronic 3 electric shower Model No 97800270 refuses to turn off the water coming through the shower head... [Read more]