ideal classic lxff ff fan flued gas boiler problem water pumping over ?
boiler works fine but will pump hot water through expansion pipe into header tank as fast as the pump is set (mainly on setting 2 or 3) any ideas to resolve problem.
see the boiler manual for correct fitting of feed and vent pipes- eg should they be into boiler tappings?
cheers euge plumbersw15attalktalk.net
euge plumbersw15attalktalk.net
March 2010
If Cold Feed Pipe and Vent Pipe are close coupled in the airing cupboard it is most likeley that there is a blockage in the small section of pipe between them, this is very common, the blocked section of pipe work should be cut out and cleared or repalced with new
www.elanar.co.uk
July 2009
sounds like a blockage in the system.
Ian
July 2009